Skip to main content

Micro Matic MMPP4307-PKG Air-Cooled Pro-Line Draft Beer System Power Pack - 1.5 HP

Micro Matic

$7,981.52
(No reviews yet) Write a Review
SKU:
MMPP4307-PKG
Weight:
295.00 LBS
Shipping:
Calculated at Checkout
Cooling:
Air Cooled
Filter Type:
System Power Packs
Refrigerant Type:
R-404A
Total BTU:
11,500 BTU
email_price:
no
Tags:
Draft Beer System Power Rack
Label Option type:
rectangles
Net Price:
7045.83
msrp_price:
no
Ship From:
34604
Product Taxonomy:
CulinaryDepot>>Commercial Refrigerator>>Refrigeration Parts and Accessories>>Bar Refrigeration Draft Parts and Accessories>>Couplers, Distributors, & Regulators
call_price:
no
map_price:
no
Mfr Toll Free:
(866) 327-4159
Freight Class:
92.5
Packed By:
1 Each
add_to_cart:
no
MAP Price:
7981.52
Manufacturer:
Micro Matic
login_price:
no
List Price:
15657.40
Taxonomy Weight:
295
Amps:
11.5
Phase:
1-Ph
cETLus Certified:
Yes
Hertz:
60
Filter_Manufacturer:
Micro Matic
Filter_Type:
System Power Packs
Primary Image:
Micro Matic_MMPP4307-PKG.png
specsheet:
Micro Matic_MMPP4307-PKG.pdf
warranty:
Micro Matic_MMPP4307-PKG_1.pdf
Sale Price:
7981.52
Trigger BC Integration:
Y-6/24/2026_6:00PM
manual:
Micro Matic_MMPP4307-PKG_2.pdf
Voltage:
208/230v
SKU Number:
MMPP4307-PKG__1152
Keyfeatures5:
Compact 38" W x 20" D x 36" H footprint
Keyfeatures4:
Digital thermostat for temperature control
Keyfeatures6:
R-404A refrigerant with 11,500 BTU
Keyfeatures:
Air-cooled 1.5 HP compressor for cooling
Keyfeatures3:
Two 80 gph vane pumps with 1/3 HP motors
Keyfeatures2:
11.5 gallon glycol bath with sight glass
short_description:
Built for continuous service, the Micro Matic MMPP4307-PKG power pack offers a 1.5 HP compressor and 11,500 BTU cooling to maintain draft temperatures.
Lead Time:
2 - 3 Business Days
PRO:
yes
Adding to cart… The item has been added
Stop sacrificing control for convenience. This air-cooled power pack combines industrial-grade refrigeration with targeted fluid circulation to maintain consistent draft temperature across multiple lines while reducing footprint and service complexity. Operators will appreciate measurable temperature control, a robust compressor, and integrated pumps that sustain dispense quality under heavy use.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug power and drain glycol before service. Remove cover and wipe interior with a mild detergent; use non-abrasive cloths. Flush pumps and lines with approved sanitizer; circulate per manufacturer instructions. Clean condenser fins with low-pressure air to maintain heat exchange. Inspect seals and fittings, tighten or replace worn parts. Dry components fully, reconnect power, and verify thermostat and pump operation to prevent contamination, fires, and costly failures.#@@#Additional Info#@#Micro Matic's MMPP4307-PKG power pack features a 1.5 HP compressor, 11,500 BTU capacity, and an 11.5 gallon glycol bath. It includes two 80 gph pumps, digital thermostat, insulated cabinet, R-404A refrigerant, and cETLus certification.#@@#General Info#@#Description #@# Stop sacrificing control for convenience. This air-cooled power pack combines industrial-grade refrigeration with targeted fluid circulation to maintain consistent draft temperature across multiple lines while reducing footprint and service complexity. Operators will appreciate measurable temperature control, a robust compressor, and integrated pumps that sustain dispense quality under heavy use. #@@# Glycol Bath#@# The system includes an 11.5-gallon glycol bath with an exterior sight glass that enables continuous coolant circulation and clear visual monitoring. Technicians can verify fluid levels at a glance and avoid service interruptions that compromise pour temperature. #@@# Circulating Pumps#@# Two 80 gph vane circulating pumps, each driven by a 1/3 HP motor, deliver controlled coolant flow to long-run draught lines. Operators achieve uniform cooling across multiple faucets, preserving head retention and flavor stability during peak service. #@@# Compressor Capacity#@# A 1.5 HP compressor provides 11,500 BTU of cooling capacity using R404A refrigerant, enabling rapid recovery and steady thermal performance. Managers can rely on sustained load handling when multiple taps run simultaneously. #@@# Digital Thermostat#@# An onboard digital thermostat allows precise setpoint control and repeatable temperature management across shifts. Facility staff can document and maintain target ranges, supporting quality assurance and regulatory compliance. #@@# Air-Cooled Design#@# The air-cooled cabinet reduces installation complexity by eliminating external glycol chillers and bulky plumbing. Kitchen and bar teams gain usable space and simplify maintenance while still meeting cooling requirements for draft systems. #@@# Built For Service#@# The insulated cabinet ships with a removable cover and NEMA 6-20P power configuration to facilitate installation and routine maintenance. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect condenser and air intakes weekly to prevent airflow restriction and maintain 11,500 BTU cooling capacity. Drain and replace glycol in the 11.5 gallon bath every six months; verify exterior sight glass level and top to specification. Calibrate the digital thermostat quarterly and document set points. Clean pumps and check 1/3 HP motors for vibration; tighten mounts. Confirm electrical connections to NEMA 6-20P and test overload protection monthly.