Stop sacrificing uptime for capacity. This air-cooled Pro-Line power pack combines a 1.5 HP compressor with focused circulation to maintain consistent draft performance in high-volume pouring environments. Operators gain a compact, service-ready refrigeration module engineered for continuous duty and precise temperature control.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug unit and drain glycol per manufacturer instructions. Remove cover and wipe cabinet interior with mild detergent and warm water. Clean condenser fins with a fin comb and vacuum debris to maintain 11,500 BTU efficiency. Sanitize pump housings and exterior with EPA-approved cleaner safe for food service. Inspect seals, fittings, and the digital thermostat for damage; tighten or replace parts as needed. Refill glycol to 11.5 gallons, restore power, and verify 208/230v operation.#@@#Additional Info#@#Micro Matic’s MMPP4307-PKG-3 power pack features a 1.5 HP compressor, 11,500 BTU cooling, and an 11.5-gallon glycol bath. It includes three 80 gph pumps, a digital thermostat, R-404A refrigerant, and a compact footprint of 38" W x 30" D x 36" H.#@@#General Info#@#Description #@#
Stop sacrificing uptime for capacity. This air-cooled Pro-Line power pack combines a 1.5 HP compressor with focused circulation to maintain consistent draft performance in high-volume pouring environments. Operators gain a compact, service-ready refrigeration module engineered for continuous duty and precise temperature control.
#@@# Circulating Pumps#@#
Three 80 gph vane pumps provide directed glycol flow to tap lines, sustaining temperature stability across multiple draft points. Technicians can expect redundant circulation with each pump driven by a 1/3 HP motor, reducing the risk of flow interruption during peak periods.
#@@# Glycol Reservoir#@#
An 11.5-gallon glycol bath with an exterior sight glass simplifies level checks and reduces maintenance time. Staff can monitor fluid visually and refill without opening the insulated cabinet, preserving cold recovery and system efficiency.
#@@# Temperature Control#@#
A digital thermostat delivers repeatable setpoints for consistent line temperatures, which preserves product quality and minimizes foam. Operators can program precise control to match serving requirements and ambient load variations.
#@@# Compressor Performance#@#
The 1-1/2 HP compressor rated to 11,500 BTU supports sustained cooling capacity for extensive tap networks. Engineers will note the unit runs on 208/230v 60 Hz single-phase power with a 13.0 amp draw and NEMA 6-20P plug configuration for straightforward integration.
#@@# Refrigerant And Cooling#@#
The system uses R-404A refrigerant in an air-cooled configuration to remove thermal load without external glycol chillers. Facility planners will appreciate the absence of water cooling infrastructure and the simplified footprint for backbar or cellar installations.
#@@# Construction And Certification#@#
The insulated cabinet and cover improve thermal retention while the exterior sight glass and serviceable layout reduce downtime during routine checks.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect condenser fins weekly and remove dust with a soft brush to preserve 11,500 BTU performance. Drain and replace glycol bath fluid every 12 months; verify 11.5 gallon level via the exterior sight glass and test the digital thermostat accuracy. Tighten electrical connections to NEMA 6-20P specifications and confirm 208/230v supply and 13 amp draw. Flush pump lines and sanitize alloy surfaces to prevent biofilm and maintain cooling efficiency.