Stop sacrificing temperature control for throughput. This air-cooled draft power pack combines a 1.5 HP compressor with four dedicated circulating pumps to maintain long runs and consistent pour quality in high-volume draft programs. Operators benefit from a compact, serviceable system designed for continuous duty in commercial environments.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug unit and shut off power at the breaker. Drain glycol bath and dispose per local rules. Wipe interior and exterior with mild detergent and warm water, using non-abrasive cloths. Flush pumps and lines with manufacturer-recommended cleaner, then rinse with potable water. Clean condenser fins with soft brush and vacuum to remove dust. Inspect seals and fasteners; tighten or replace as needed. Refill glycol to 11.5 gallons, set digital thermostat, then restore power and check for leaks.#@@#Additional Info#@#Micro Matic’s MMPP4307-PKG-4 power pack offers 1.5 HP with 11,500 BTU cooling, a 11.5-gallon glycol bath, four 80 gph pumps, digital thermostat, insulated cabinet, R-404A refrigerant, and cETLus certification.#@@#General Info#@#Description #@#
Stop sacrificing temperature control for throughput. This air-cooled draft power pack combines a 1.5 HP compressor with four dedicated circulating pumps to maintain long runs and consistent pour quality in high-volume draft programs. Operators benefit from a compact, serviceable system designed for continuous duty in commercial environments.
#@@# Cooling Capacity#@#
The 11,500 BTU cooling capacity supports sustained glycol temperatures for long tap lines, ensuring that the product remains within target ranges during extended service periods. Digital thermostat control provides repeatable setpoints and minimizes manual intervention for effective temperature management.
#@@# Glycol Reservoir#@#
An 11.5-gallon glycol bath with an exterior sight glass allows for clear visual checks of fluid level and condition without needing to open the cabinet. Technicians can quickly confirm fill status and diagnose circulation issues, reducing downtime during peak service.
#@@# Circulation Pumps#@#
Four 80 gph vane pumps, each powered by a 1/3 HP motor, deliver redundant, balanced flow to multiple beer circuits and minimize pressure fluctuations at the taps. Distributing the load across pumps ensures consistent line temperatures and isolates failures to a single circuit, allowing for continued operation.
#@@# Compressor Performance#@#
A 1-1/2 HP compressor matched to R-404A refrigerant provides robust cooling for dense keg rooms and long draught runs while operating on 208/230v, 60 Hz, single-phase power. The unit draws 14.5 amps and comes with a NEMA 6-20P plug for easy electrical integration.
#@@# Cabinet Construction#@#
Insulated cabinet construction with a removable cover limits thermal gain and protects internal components from ambient heat and debris. Service panels and an organized internal layout facilitate routine maintenance and component replacement.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect condenser fins monthly and remove debris to maintain 11,500 BTU capacity. Drain and replace glycol yearly; verify bath holds 11.5 gallons and check sight glass level before startup. Clean pump inlets and strainers on the four 80 gph vane circulating pumps; service seals if flow drops. Calibrate the digital thermostat quarterly and log temperatures. Verify NEMA 6-20P plug, 208/230v supply, 14.5 amps load, and secure connections.