Stop sacrificing uptime for inconsistent cooling. This glycol-cooled power pack delivers continuous temperature control for tap lines while supporting high-volume pouring with a 1 HP compressor and triple pump assembly, designed for remote installations where precision is crucial. Engineered for commercial draft systems, the unit balances power and control to keep product lines chilled to specification.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug the pack and let components cool before working on the glycol bath. Drain the bath per manufacturer guidelines, dispose of glycol as per local regulations, and flush with clean water. Wipe exterior panels with a mild detergent and soft cloth. Clean condenser coils with a brush and vacuum; inspect coils monthly. Remove grime from pump housings and motor mounts; lubricate bearings per Micro Matic specs. Inspect electrical connections and seals; tighten or replace worn parts.#@@#Additional Info#@#Micro Matic’s Pro-Line MMPP4305-PKG-3-R Glycol Power Pack offers 1 HP cooling with R-134a refrigerant and 7,250 BTU capacity for glycol-cooled draft systems.#@@#General Info#@#Description #@#
Stop sacrificing uptime for inconsistent cooling. This glycol-cooled power pack delivers continuous temperature control for tap lines while supporting high-volume pouring with a 1 HP compressor and triple pump assembly, designed for remote installations where precision is crucial. Engineered for commercial draft systems, the unit balances power and control to keep product lines chilled to specification.
#@@# Power Limited Distance#@#
Position the remote compressor no farther than 50 feet from the bath to maintain optimal refrigerant performance and prevent head pressure issues. Contractors must plan line runs accordingly to preserve system efficiency and meet installation requirements.
#@@# Glycol Cooling#@#
Glycol cooling maintains line temperatures uniformly across long runs, reducing foam and product waste during peak service. The closed glycol bath pairs with the R-134a refrigeration circuit to stabilize thermal transfer for consistent pour quality.
#@@# Compressor Output#@#
A 1 HP compressor provides 7,250 BTU of cooling capacity to support multiple draft lines under load. Operators will observe sustained temperature control during continuous dispensing in high-turn settings.
#@@# Triple Pump Assembly#@#
The integrated triple pump and motor offer redundancy and balanced flow to multiple faucets, minimizing pressure fluctuation and ensuring steady dispense rates. Maintenance teams gain simplified access to pumps for service without disrupting the refrigeration loop.
#@@# Electrical Configuration#@#
The unit ships configured for 208/230v operation and uses a NEMA 6-20P connection, matching common commercial electrical infrastructure. Electricians must hardwire the glycol bath circuit per local code to complete the installation.
#@@# Refrigerant Specification#@#
The system uses R-134a refrigerant and requires a refrigeration contractor to furnish freon tube and connection services.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Maintain the Micro Matic MMPP4305-PKG-3-R by inspecting glycol level weekly and topping to manufacturer specification. Drain and replace glycol annually; flush lines with approved cleaner before refill. Clean condenser fins monthly and verify 208/230v supply and NEMA 6-20P connections for damage. Test compressor vibration and tighten mounts quarterly. Monitor refrigerant R-134a pressure and repair leaks immediately to prevent capacity loss.