For high-volume bars and institutional pouring operations that cannot tolerate downtime, this glycol-cooled power pack delivers continuous temperature control and reliable pump performance in a compact package. It pairs a 3/4 HP compressor with a triple pump and motor assembly to maintain line temperatures and consistent foam control across multiple beer lines. Operators gain predictable draft quality while technicians find straightforward service points and standard electrical and refrigerant interfaces.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug power and lock out electrical supply before you start. Drain glycol and collect in approved containers; dispose per local rules. Wipe exterior with non-abrasive cleaner and a soft cloth. Flush lines with manufacturer-approved glycol solution, then purge air and verify 50-foot max remote run. Clean condenser fins with low-pressure air; remove debris from fan housing. Inspect seals, fittings, and the NEMA 6-20P cord; tighten or replace as needed. Refill to spec and restore power.#@@#Additional Info#@#Micro Matic's MMPP4303-PKG-3-R Pro-Line glycol power pack delivers 0.75 HP and 5,100 BTU cooling for remote draft systems, uses R-134a refrigerant, operates on 208/230v, and weighs 175 pounds.#@@#General Info#@#Description #@#
For high-volume bars and institutional pouring operations that cannot tolerate downtime, this glycol-cooled power pack delivers continuous temperature control and reliable pump performance in a compact package. It pairs a 3/4 HP compressor with a triple pump and motor assembly to maintain line temperatures and consistent foam control across multiple beer lines. Operators gain predictable draft quality while technicians find straightforward service points and standard electrical and refrigerant interfaces.
#@@# Compressor Performance#@#
A 3/4 HP compressor provides 5,100 BTU of cooling capacity to sustain glycol bath temperatures under heavy draw conditions. Service teams can install the unit where cooling demand remains stable, and the rated capacity supports simultaneous runs on multiple draft lines.
#@@# Triple Pump Assembly#@#
The integrated triple pump and motor assembly supplies consistent flow to three independent circuits, preserving line balance and reducing cross-contamination risk. Staff can tune individual heads to match run length and dispense profile for each product.
#@@# Glycol Cooling#@#
The system uses glycol-cooled circulation to maintain stable product temperatures along long dispensing runs, suitable for installations where remote lines extend up to 50 feet. Planners can position the compressor remotely while keeping the bath within specified distance limits to ensure thermal integrity.
#@@# Refrigerant and Electrical#@#
The unit operates on R-134a refrigerant and requires a hardwired bath connection, with a NEMA 6-20P plug specified for compressor mains. Installers must handle freon tube and connection work through a certified refrigeration contractor to comply with local codes.
#@@# Service Access#@#
Technicians access major components through straightforward panels and conventional fittings, which streamlines routine maintenance and reduces service time.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect glycol level weekly; top to manufacturer specs and record gallons added and date. Flush lines quarterly with approved cleaner to prevent biofilm; follow dwell times. Clean condenser fins monthly to maintain 5,100 BTU performance. Verify electrical connections and NEMA 6-20P plug integrity; tighten loose terminals. Check pump seals and replace worn parts yearly. Service refrigeration contractor for freon tube installation and hardwire bath per CSA guidelines.