Stop compromising throughput for temperature control. This air-cooled draft system power pack combines a robust compressor with precision circulation to maintain consistent glycol temperatures across high-volume tap lines while supporting multiple dispensing points with stable flow rates.
Equipped with a 3/4 HP compressor and R-134a refrigerant, the unit delivers 5,100 BTU of cooling capacity and operates on 208/230v/60/1-ph power. The design targets commercial bars, restaurants, hospitals, universities, and large-scale catering operations that require reliable temperature regulation and continuous service.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug the unit and drain the 11.5 gallon glycol bath. Remove the cover and wipe the insulated cabinet with a mild detergent. Clean pumps and exterior with non-abrasive cloth. Flush glycol lines and sanitize beer-contact surfaces per CSA guidelines. Clean condenser coil and fan to remove dust for optimal 5,100 BTU performance. Inspect seals and electrical cord; reconnect power only when dry and secure.#@@#Additional Info#@#Micro Matic MMPP4303-PKG-3 Air-cooled Pro-Line draft beer power pack offers 3/4 HP refrigeration, 5,100 BTU capacity, 11.5 liters glycol bath, three 80 gph pumps, digital thermostat, insulated cabinet, R-134a refrigerant, and cETLus certification.#@@#General Info#@#Description #@#
Stop compromising throughput for temperature control. This air-cooled draft system power pack combines a robust compressor with precision circulation to maintain consistent glycol temperatures across high-volume tap lines while supporting multiple dispensing points with stable flow rates.
Equipped with a 3/4 HP compressor and R-134a refrigerant, the unit delivers 5,100 BTU of cooling capacity and operates on 208/230v/60/1-ph power. The design targets commercial bars, restaurants, hospitals, universities, and large-scale catering operations that require reliable temperature regulation and continuous service.
#@@# Pumping Capacity#@#
Three 80 gph vane circulating pumps provide dedicated flow for segregated lines and rapid recovery under peak draw. The arrangement uses individual 1/3 HP motors per pump to isolate failures and preserve circulation to remaining lines, reducing service interruptions.
#@@# Glycol Reservoir#@#
An 11.5-gallon glycol bath holds sufficient volume for maintaining thermal mass across extended runs and multiple taps. An exterior sight glass enables visual level checks without opening the insulated cabinet, supporting faster routine maintenance.
#@@# Temperature Control#@#
An integrated digital thermostat permits precise setpoint control and straightforward adjustments for seasonal load changes. The system uses active feedback to minimize temperature drift along long run lengths and between service sessions.
#@@# Cabinet Insulation#@#
Insulated cabinet construction with a removable cover reduces heat ingress and improves compressor efficiency during continuous operation. Air-cooled ventilation simplifies installation compared to remote condenser loops and lowers plumbing complexity.
#@@# Electrical Compatibility#@#
The unit ships with a NEMA 6-20P configuration and draws 11.0 amps, facilitating integration into standard commercial circuits while meeting cETLus safety certification.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect condenser fins weekly and remove debris to maintain 5,100 BTU cooling capacity. Drain and replace the 11.5 gallon glycol bath per manufacturer schedule; verify fluid level via the exterior sight glass. Calibrate the digital thermostat monthly and record settings. Lubricate three 80 gph vane circulating pumps according to service intervals and confirm each 1/3 HP motor operates within 11 amps at 208/230v. Tighten electrical connections and replace worn seals promptly.