Stop compromising throughput for control. This air-cooled power pack delivers industrial-grade circulation, thermal management, and electrical compatibility to keep draft lines chilled and pouring consistently in high-volume venues. Designed for operations that require reliable pressure, flow, and temperature stability, this unit integrates pump capacity, glycol management, and compliant electrical components into one service-ready assembly.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug the power pack and close the gas and beverage lines. Drain the 11.5 gallon glycol bath, then flush with clean water and wipe with a mild detergent. Clean condenser fins and fan housings to remove grease and dust; inspect and clear vents to prevent fire risk. Sanitize fittings, couplers, and pumps with food-grade sanitizer to remove bacteria. Check seals and electrical cords for wear. Refill glycol to specification, secure the cover, then reconnect power and verify thermostat operation.#@@#Additional Info#@#Micro Matic's MMPP4305-PKG-3 air-cooled Pro-Line power pack provides 1 HP cooling at 7,250 BTU using R-134a refrigerant.#@@#General Info#@#Description #@#
Stop compromising throughput for control. This air-cooled power pack delivers industrial-grade circulation, thermal management, and electrical compatibility to keep draft lines chilled and pouring consistently in high-volume venues. Designed for operations that require reliable pressure, flow, and temperature stability, this unit integrates pump capacity, glycol management, and compliant electrical components into one service-ready assembly.
#@@# Circulation Pumps#@#
Three 80 gph vane circulating pumps provide sustained flow for multiple tap runs and longline configurations. Operators gain redundancy and balanced distribution that maintain consistent product temperature across several taps.
#@@# Glycol Bath Capacity#@#
An 11.5-gallon glycol bath supports extended thermal buffering and reduced temperature drift during peak service. Technicians monitor fluid levels via the exterior sight glass, enabling rapid visual checks without opening the insulated cabinet.
#@@# Temperature Control#@#
A digital thermostat enables precise setpoint management and repeatable temperature control for line chilling. Staff achieve target temperatures quickly and maintain them through variable demand periods, reducing spoilage and foam variation.
#@@# Compressor Performance#@#
A 1 HP compressor rated for R-134a refrigeration delivers 7,250 BTU of cooling power to handle sustained loads. Facility engineers benefit from a unit that meets common commercial demands while operating on 208/230v and 12.5 amps.
#@@# Electrical Interface#@#
The assembly ships with a NEMA 6-20P connection and single-phase 60 hertz compatibility for straightforward integration into standard service circuits. Maintenance teams simplify installation and reduce downtime with familiar electrical connections and cETLus certification.
#@@# Cabinet Design#@#
An insulated cabinet with cover preserves glycol temperature and reduces cycling frequency for improved energy use.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect condenser and fan assemblies weekly to remove dust and debris that reduce heat transfer. Drain and replace glycol every six months, measuring concentration and topping to the 11.5-gallon capacity for freeze protection. Verify digital thermostat accuracy with a calibrated thermometer and recalibrate if needed. Tighten electrical connections and check compressor amp draw at 12.5 amps to detect faults. Clean sight glass and replenish refrigerant R-134a only by certified technicians.