Skip to main content

AccuTemp N61201E060 SGL-LP 6 Pans Liquid Propane Convection Steamer Connected Evolution Boilerless - 60,000 BTU

AccuTemp

$16,030.85
(No reviews yet) Write a Review
SKU:
N61201E060 SGL-LP
Weight:
305.00 LBS
Shipping:
Calculated at Checkout
SKU Number:
N61201E060 SGL__1178
Filter Type:
Convection Steamers
Oven Type:
Convection Steamer
email_price:
no
Tags:
Steamer, Convection, Gas, Boilerless, Floor Model
Label Option type:
rectangles
Net Price:
13152.58
msrp_price:
no
Product Taxonomy:
CulinaryDepot>>Restaurant Equipment>>Cooking Equipments>>Steam Cooking Equipments>>Commercial Steamer
RoundUp/RoundDown:
no
Other Available Options:
Liquid Propane
call_price:
no
map_price:
yes
Mfr Toll Free:
(800) 210-5907
MSP:
0
add_to_cart:
no
Days to Return:
85
MAP Price:
16030.85
Manufacturer:
AccuTemp
login_price:
no
Product ID:
4916ee79-ba54-df11-beff-001ec95274b6
List Price:
29147.00
Trigger BC Integration:
Y-6/19/2026_1:05PM
Taxonomy Weight:
305
Phase:
1-Ph
Hertz:
60
Filter_Power Type:
Liquid Propane
Filter_Steam Source:
Boilerless
Filter_Pan Capacity:
5 - 9 Pans
Filter_Type:
Convection Steamers
Primary Image:
AccuTemp_N61201E060 SGL-LP.png
Alternate Image:
305
Sale Price:
16030.85
other_types:
N61201E060 SGL-LP$Liquid Propane#@#N61201E060 SGL-NG$Natural Gas
specsheet:
AccuTemp_N61201E060 SGL-LP.pdf
warranty:
AccuTemp_N61201E060 SGL-LP_1.pdf
manual:
AccuTemp_N61201E060 SGL-LP_2.pdf
Ship From:
46774
NSF Certified:
Yes
Energy Efficiency:
ENERGY STAR
Pan Capacity per Compartment:
(6) 12" x 20" x 2-1/2" Deep
Freight Class:
85
Packed By:
1 Each
Made in USA:
Yes
ENERGY STAR®:
Yes
cULus Certified:
Yes
Filter_Manufacturer:
AccuTemp
Filter_Style:
Floor Model
Voltage:
120v
Filter_Made in America:
Yes
Power Type:
Liquid Propane
Pan Capacity:
6 Pans
Total BTU:
60,000 BTU
Filter_Total BTU:
27,000 - 84,000 BTU
Style:
Floor Model
Item Type:
Convection Steamers
Operation:
Boilerless
Filter_NSF Listed:
Yes
UL EPH Classified:
Yes
Real Weight:
305
Real Width:
30
Real Height:
63
Keyfeatures5:
ENERGY STAR, cULus, UL EPH listed
Keyfeatures4:
Needs water/drain, no filtration
Keyfeatures6:
Made in USA floor model
Keyfeatures:
60,000 BTU propane boilerless steam
Keyfeatures3:
Digital controls, Steam Vector Tech
Keyfeatures2:
Holds 6 pans 12"x20"x2-1/2"
short_description:
AccuTemp N61201E060 SGL-LP steamer holds six 12" x 20" x 2-1/2" pans, operates boilerless on liquid propane, and features digital controls, ENERGY STAR, cULus, and UL EPH certifications.
Lead Time:
2 - 3 Business Days
is free shipping:
Yes
PRO:
yes
Adding to cart… The item has been added
When kitchen throughput demands consistency, this convection steamer ensures controlled steam performance for high-volume operations. It holds six 12" x 20" x 2-1/2" pans and uses 60,000 BTU with liquid propane, enabling continuous cooking without a boiler. Digital controls and Steam Vector Technology deliver repeatable results, while ENERGY STAR certification lowers utility costs.
LongDescription#@#NA#@@#Cleaning Instructions#@#Turn off gas and let steamer cool. Drain water, open valve, and flush with clean water. Wipe chamber and gaskets with mild detergent; avoid abrasives. Clean exterior with non-abrasive cleaner. Wash pans and racks with soapy water; check seals and hinges. Clean condenser and vents monthly to prevent grease and fire risk. Follow service schedule to maintain efficiency and pass inspections.#@@#Additional Info#@#AccuTemp N61201E060 SGL-LP is a 6-pan boilerless convection steamer with Steam Vector Technology, 60,000 BTU output, liquid propane, 120v power, ENERGY STAR, NSF Certified, cULus, UL EPH listings, and a selectable stand. Made in USA.#@@#General Info#@#Description #@# When kitchen throughput demands consistency, this convection steamer ensures controlled steam performance for high-volume operations. It holds six 12" x 20" x 2-1/2" pans and uses 60,000 BTU with liquid propane, enabling continuous cooking without a boiler. Digital controls and Steam Vector Technology deliver repeatable results, while ENERGY STAR certification lowers utility costs. #@@# Pan Capacity#@# Holds Six Pans for Scalable Output The unit fits six full-size 12" x 20" pans per compartment, supporting batch cooking and staggered loads to handle service peaks. Operators can stage products across pans to optimize yield and maintain consistent results. #@@# Steam Technology#@# Boilerless Steam Vector System Steam Vector Technology creates convection steam without a boiler, ensuring rapid heat transfer and shorter cycles. This system eliminates boiler maintenance and water filtration needs, reducing service demands. #@@# Fuel And Power#@# Liquid Propane with Standard Electrical Powered by liquid propane for high BTU output, it uses 120v/60/1-ph electricity for controls, drawing 1.0 amp via a NEMA 5-15P cord. This setup supports installations where gas provides primary heat and standard electricity powers electronics. #@@# Control Interface#@# Digital Controls for Consistency The digital system offers programmable cycles and precise time/temperature management, ensuring consistent quality. Staff training focuses on simple set selections, minimizing manual adjustments and operator variability. #@@# Construction And Compliance#@# Commercial Floor Model, Made in USA This floor-model steamer features durable commercial-grade construction, cULus listing, UL EPH classification, and NSF certification for foodservice use. ENERGY STAR certification confirms efficient, sustainable operation. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#To maintain the AccuTemp N61201E060 SGL-LP convection steamer, drain and flush the water circuit weekly to prevent mineral buildup. Clean chamber and racks after each shift with nonabrasive detergent and hot water. Inspect door gaskets daily for tears and replace when compression fails. Purge gas lines and verify 60,000 BTU combustion components quarterly. Test digital controls and water/drain connections monthly. Record maintenance actions and adhere to manufacturer service intervals.