Stop compromising operational uptime for cooling efficiency. This water-cooled draft system power pack delivers focused chilling capacity and continuous glycol circulation to maintain consistent keg temperatures during peak service, increasing draft line stability and reducing product waste. Facility managers and bar operators gain a compact, hardwired unit engineered for integrated installations and continuous duty.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug power and close water supply before cleaning. Drain glycol bath and dispose per local rules. Wipe exterior and sight glass with mild detergent and soft cloth. Flush pumps and condensate lines with clean water; run briefly to clear residue. Clean condenser water connections and replace clogged filters. Inspect door seals and fasteners; tighten as needed. Restart system and verify 115v supply, 17.2 amps draw, and thermostat function.#@@#Additional Info#@#Micro Matic’s MMPP4301-PKG-WC water-cooled Pro-Line power pack offers 0.33 HP cooling, a 1/3 HP compressor, 2,300 BTU capacity, dual 80 gph pumps, and a digital thermostat.#@@#General Info#@#Description #@#
Stop compromising operational uptime for cooling efficiency. This water-cooled draft system power pack delivers focused chilling capacity and continuous glycol circulation to maintain consistent keg temperatures during peak service, increasing draft line stability and reducing product waste. Facility managers and bar operators gain a compact, hardwired unit engineered for integrated installations and continuous duty.
#@@# Circulating Pumps#@#
Two 80 gph vane pumps provide high-volume glycol flow, ensuring rapid thermal exchange across long run lengths. Users will maintain tight temperature control through sustained circulation, reducing foam and preserving pour quality under heavy tap counts.
#@@# Glycol Reservoir#@#
The system contains an 11.5-gallon glycol bath with an exterior sight glass for immediate fluid level verification. Technicians can inspect charge at a glance and schedule service proactively, minimizing downtime and avoiding unexpected warm-ups.
#@@# Temperature Control#@#
A digital thermostat governs chilling operations and displays setpoint accuracy for precise control. Operators achieve repeatable line temperatures that protect flavor profiles and reduce the need for keg rotation or corrective cooling.
#@@# Compressor Performance#@#
A 1/3 HP compressor with 2,300 BTU capacity supports continuous load while balancing energy draw. Facilities can rely on consistent refrigeration output while matching electrical availability on standard 115v/60/1-ph circuits.
#@@# Compact Footprint#@#
The cabinet measures 30 inches wide by 18 inches deep by 28.75 inches high, offering a small footprint for underbar or remote room mounting. Engineers will integrate the unit where space constraints exist without sacrificing pump or reservoir capacity.
#@@# Field Compatibility#@#
The unit ships with 3/8 inch female NPT fittings and uses R-134a refrigerant, plus a NEMA L5-30P plug for secure power connections.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect circulating pumps weekly and tighten fittings to prevent leaks. Drain and replace glycol every 12 months, measuring volume in gallons or liters to maintain 11.5 gallon capacity. Clean exterior sight glass with nonabrasive cleaner and verify digital thermostat accuracy monthly. Flush water-cooling lines quarterly and verify NEMA L5-30P electrical connections while unit is deenergized. Replace worn seals and service compressor per CSA guidelines to preserve performance.