Handle high-volume draft operations without sacrificing temperature control or reliability. This water-cooled power pack delivers continuous circulation and consistent cooling for long tap runs, enabling tight temperature hold across multiple lines while minimizing heat load in the keg room. Operators find that precise control and rugged construction reduce service interruptions and preserve product quality under sustained use.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug power and drain glycol. Remove cover and wipe interior with a mild soap solution and a soft cloth. Flush pump and lines with potable water until clear. Clean condenser or water-cooling connections to remove grease and scale. Inspect seals and fittings; tighten or replace as needed. Rinse and dry all surfaces; refill with specified glycol to the correct gallons or liters. Reconnect power and verify thermostat and pump operate within rated amps and voltage.#@@#Additional Info#@#Micro Matic’s MMPP4301-WC power pack offers 0.33 HP cooling with a 1/3 HP compressor, 2,300 BTU capacity, 11.5-gallon glycol bath, R-134a refrigerant, and an 80 gph circulating pump for draft beer temperature control.#@@#General Info#@#Description #@#
Handle high-volume draft operations without sacrificing temperature control or reliability. This water-cooled power pack delivers continuous circulation and consistent cooling for long tap runs, enabling tight temperature hold across multiple lines while minimizing heat load in the keg room. Operators find that precise control and rugged construction reduce service interruptions and preserve product quality under sustained use.
#@@# Pump and Motor#@#
An 80 gph vane circulating pump paired with a 1/3 HP motor provides steady glycol flow to maintain stable line temperatures across extended runs. Technicians report that uniform circulation reduces hot spots and limits pressure fluctuations during peak service.
#@@# Glycol Reservoir#@#
A built-in 11.5-gallon glycol bath holds sufficient fluid volume for extended operation and helps dampen temperature swings during heavy draw periods. The exterior sight glass simplifies level checks and speeds routine maintenance without cabinet access.
#@@# Digital Temperature Control#@#
A digital thermostat offers setpoint accuracy and repeatable control for chilled glycol circuits to protect head retention and flavor integrity. Staff can program and verify temperatures quickly, improving consistency between shifts.
#@@# Water Cooling Design#@#
Water-cooled refrigeration removes heat efficiently and reduces compressor workload in tight mechanical spaces where air-cooled systems struggle. Facilities with high ambient heat benefit from lower condenser temperatures and reduced room heat gain.
#@@# Refrigeration System#@#
A 1/3 HP compressor charged with R-134a delivers 2,300 BTU of cooling capacity, suitable for moderate draft installations and multiple tap lines. The cETLus certification verifies equipment compliance with North American safety standards.
#@@# Electrical and Service#@#
The unit operates on 115v/60/1-Ph power, draws 11.6 amps, and ships with a NEMA 5-15P plug for straightforward connection to standard circuits.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the circulating pump daily for leaks and noise. Tighten fittings weekly to prevent glycol loss. Drain and replace the 11.5-gallon glycol bath as per the manufacturer schedule, and check the sight glass for proper level. Clean condenser water connections and strainers monthly for 2,300 BTU efficiency. Verify thermostat calibration quarterly and record setpoints. Replace R-134a or compressor parts only with CSA-compliant components.