Stop compromising safety for convenience. This galvanized fixed flame guard baffle filter streamlines exhaust filtration while ensuring code compliance for commercial kitchens. Designed for continuous operation, it fits standard 16-inch wide hoods and supports rigorous cleaning cycles with durable construction.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug equipment and remove filter. Remove loose debris and soak filter in hot water with a mild detergent for 10–15 minutes. Scrub using a soft brush along the baffle channels to dislodge grease. Rinse thoroughly with clean water and inspect for damage; replace if warped or perforated. Dry completely before reinstalling. Clean hood filters weekly; clean more often in high-use kitchens to reduce fire risk, limit bacteria, lower energy use, and meet CSA and NSF expectations.#@@#Additional Info#@#Component Hardware FG51-2516 galvanized Flame Gard baffle filter measures 25" H x 16" W x 1.75" thick, weighs 5.7 lbs, and has cULus and NSF certifications; it captures grease for exhaust hoods and simplifies maintenance with removable baffles.#@@#General Info#@#Description #@#
Stop compromising safety for convenience. This galvanized fixed flame guard baffle filter streamlines exhaust filtration while ensuring code compliance for commercial kitchens. Designed for continuous operation, it fits standard 16-inch wide hoods and supports rigorous cleaning cycles with durable construction.
#@@# Size and Fit#@#
Designed to fit a nominal 16 inches by 25 inches opening, this unit measures 1.75 inches thick and installs into common hood tracks. Installers will appreciate the consistent dimensional tolerances that reduce adjustment time during retrofit or new installation.
#@@# Galvanized Construction#@#
Constructed from galvanized steel, the filter resists corrosion in high-moisture kitchen environments and maintains structural integrity under frequent handling. Maintenance crews will find the surface easier to clean than untreated materials, reducing labor time per service cycle.
#@@# Fixed Baffle Design#@#
Engineers configured the baffle array to remain fixed, eliminating moving parts that increase failure points and simplifying routine inspection. Operators can rely on stable airflow patterns that channel grease away from plenums and into accessible collection paths.
#@@# Certifications and Compliance#@#
This filter carries cULus and NSF certifications, indicating compliance with applicable safety and sanitation standards for commercial exhaust systems. Facility managers gain documentation needed for inspections and risk assessments without additional testing.
#@@# Thickness and Capacity#@#
The 1.75-inch thickness provides multiple baffle passes to capture condensible grease and particulate under heavy cooking loads. Kitchen teams will notice reduced carryover into ductwork, which lowers fire risk and extends service intervals for downstream equipment.
#@@# Weight and Handling#@#
At approximately 5.7 pounds, the unit balances rigidity with manageable weight for single-person handling during removal and replacement.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the Component Hardware FG51-2516 baffle filter monthly and remove grease deposits to maintain airflow and reduce fire risk. Use a degreasing detergent and 150–160°F water for soak cleaning, then rinse and air dry fully before reinstalling. Check mounting clips and gaskets for wear and replace damaged parts. Record service dates and gallons of cleaning solution used to track consumption and schedule preventive maintenance consistently.