Stop compromising safety for convenience. This galvanized fixed flame guard baffle filter provides robust grease capture and flame containment for commercial exhaust hoods, enabling kitchens to maintain code compliance and reduce fire risk while sustaining required airflow. Designed for routine replacement cycles, this filter balances structural rigidity with manageable weight for fast service.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug equipment before cleaning. Remove filter FG51-1020 and soak in a degreasing solution for 10–20 minutes. Scrub both sides with a non-abrasive brush to remove grease and food residue. Rinse thoroughly with warm water and inspect seals and frame. Air dry completely before reinstalling. Clean filters weekly or more often under heavy use to reduce fire risk, prevent contamination, lower utility usage, extend equipment life, and help pass CSA and health inspections.#@@#Additional Info#@#Component Hardware FG51-1020 20" W Galvanized Fixed Flame Gard Baffle Filter measures 10" H x 20" W x 1.75" thick, weighs 3.2 lbs, and installs in exhaust hoods to control grease vapors; cULus and NSF certified for foodservice compliance.#@@#General Info#@#Description #@#
Stop compromising safety for convenience. This galvanized fixed flame guard baffle filter provides robust grease capture and flame containment for commercial exhaust hoods, enabling kitchens to maintain code compliance and reduce fire risk while sustaining required airflow. Designed for routine replacement cycles, this filter balances structural rigidity with manageable weight for fast service.
#@@# Flammable Particle Control#@#
The baffle geometry channels hot gases while trapping grease in vertical wells, preventing flame propagation into ductwork. Engineers designed the grooves to promote drainage and reduce carryover, which minimizes accumulation and maintenance intervals.
#@@# Galvanized Construction#@#
Galvanized steel resists corrosion in humid, heat-exposed environments, extending service life in high-use kitchens. Fabrication tolerances ensure a consistent fit into standard 20-inch by 10-inch housings, lowering installation time and reducing alignment issues.
#@@# Fixed Configuration#@#
The fixed, non-removable core eliminates loose components that can shift under airflow, maintaining filter integrity during heavy extraction cycles. Technicians can rely on stable performance without reconfiguring elements after cleaning or handling.
#@@# Compact Thickness#@#
At 1.75 inches overall thickness, the unit fits common ducts and hoods while preserving a low profile that does not impede the capture area. Designers benefit from the slim form factor when specifying retrofits or new installations in constrained spaces.
#@@# Safety Certifications#@#
Certified to cULus and NSF standards, the filter meets established safety and sanitary requirements for commercial kitchens. Facilities managers gain documentation that supports inspections and insurance compliance.
#@@# Service Weight#@#
With an approximate weight of 3.2 pounds, staff can remove and replace individual filters without mechanical assistance, reducing downtime during cleaning cycles.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the Component Hardware FG51-1020 filter monthly for grease buildup and physical damage. Remove the 20" x 10" galvanized baffle and soak in a degreasing solution at 120–140°F, agitate to dislodge deposits, then rinse with potable water and air dry before reinstalling. Verify gaskets and mounting hardware for corrosion; replace components that show deformation. Record service dates and rotate replacements per usage to ensure CSA, NSF and cULus compliance.