When uptime determines profit, this glycol-cooled power pack delivers controlled temperature and continuous draft performance for high-volume service environments. Designed for remote installation, the unit pairs a 1/2 HP compressor with dual pumps and a dedicated bath to circulate glycol and maintain line temperature, enabling consistent pour quality across long runs. Operators gain predictable cooling capacity and simplified integration with standard bar refrigeration systems.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug the glycol power pack and allow components to cool. Drain glycol into a labeled container following local disposal rules, then flush the bath with mild detergent and warm water. Wipe exterior with a non-abrasive cloth and inspect electrical cord and NEMA 5-15P plug for damage. Clean condenser fins with a soft brush to remove dust and maintain 3,600 BTU performance. Refill with specified R-134a-compatible glycol, verify seals, then restore power and check for leaks.#@@#Additional Info#@#Micro Matic MMPP4302-PKG-R Pro-Line glycol power pack offers 0.5 HP with dual pump, 3,600 BTU capacity, R-134a refrigerant, and NEMA 5-15P power; remote compressor must be within 50 feet, and hardwiring is needed for freon connections.#@@#General Info#@#Description #@#
When uptime determines profit, this glycol-cooled power pack delivers controlled temperature and continuous draft performance for high-volume service environments. Designed for remote installation, the unit pairs a 1/2 HP compressor with dual pumps and a dedicated bath to circulate glycol and maintain line temperature, enabling consistent pour quality across long runs. Operators gain predictable cooling capacity and simplified integration with standard bar refrigeration systems.
#@@# Compressor and Pumps#@#
A 1/2 HP compressor drives reliable refrigeration capacity rated at 3,600 BTU, providing steady cooling so taps maintain target temperatures during peak service. The dual pump and motor configuration supplies redundant glycol circulation and sustained flow rates for multiple dispense lines over extended runs.
#@@# Glycol Cooling System#@#
The closed-loop glycol bath keeps dispensing lines chilled without direct contact between refrigerant and product, reducing contamination risk and preserving flavor stability. Technicians can adjust flow and monitor bath performance to match line length and pour temperature requirements.
#@@# Remote Installation Flexibility#@#
Install the compressor remotely up to 50 feet from the glycol bath, allowing placement in mechanical rooms to reduce kitchen noise and heat load. Contractors connect the freon tube and fittings on site, which supports retrofit scenarios and tailored line routing.
#@@# Electrical and Safety Specifications#@#
Supply the bath with a hardwired electric connection to meet operational demand and ensure continuous pump power during service hours. The unit ships with NEMA 5-15P compatibility for standard power interconnections, enabling straightforward field wiring by qualified electricians.
#@@# Refrigerant and Compliance#@#
Utilize R-134a refrigerant within the sealed refrigerant circuit, consistent with common service practices and parts availability for maintenance.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect glycol level weekly and maintain between specified fill marks; top with manufacturer-recommended glycol solution to prevent freeze and microbial growth. Flush lines quarterly with approved cleaners and verify pump seals for leaks; replace worn seals immediately. Clean condenser fins monthly and verify airflow clearance. Test thermostat and safety controls after any service. Document service dates, gallons used, and compressor hours for warranty compliance.