Stop sacrificing control for convenience. This air-cooled draft power pack delivers stable glycol circulation, targeted cooling, and dependable compressor performance to support uninterrupted draft operations in busy bars, restaurants, and hospitality venues. Engineered for continuous duty, the unit balances capacity and efficiency, allowing staff to maintain consistent line temperatures and product quality during peak service periods.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug the power pack and lock out the circuit. Drain and remove condenser debris with a soft brush; clean coil fins with a fin comb and vacuum. Empty the 11.5 gallon glycol bath, inspect the sight glass, and flush with manufacturer-approved glycol mix; refill to spec. Sanitize pump fittings and couplers with food-safe sanitizer. Wipe exterior with non-abrasive cleaner. Verify seals, thermostat setpoint, and electrical connections before restoring power.#@@#Additional Info#@#Micro Matic MMPP4302-PKG air-cooled Pro-Line power pack features an 11.5-gallon glycol bath, dual 80 gph pumps, 1/2 HP compressor rated 3,600 BTU, digital thermostat, insulated cabinet, 115v/60/1-ph, 21 amps, NEMA L5-30P, cETLus certified.#@@#General Info#@#Description #@#
Stop sacrificing control for convenience. This air-cooled draft power pack delivers stable glycol circulation, targeted cooling, and dependable compressor performance to support uninterrupted draft operations in busy bars, restaurants, and hospitality venues. Engineered for continuous duty, the unit balances capacity and efficiency, allowing staff to maintain consistent line temperatures and product quality during peak service periods.
#@@# Pumping Capacity#@#
Two 80 gph vane circulating pumps provide redundant flow and sufficient throughput for multi-tap runs, ensuring consistent glycol movement through long run lengths. Operators can rely on the dual-pump arrangement to reduce pressure on a single pump and minimize service interruptions, enhancing overall reliability.
#@@# Glycol Reservoir#@#
An 11.5-gallon glycol bath offers substantial thermal mass to stabilize line temperatures during heavy draw periods. Technicians can easily monitor fluid level and condition via the exterior sight glass, simplifying routine checks and top-offs, which helps maintain optimal performance.
#@@# Temperature Control#@#
A digital thermostat provides precise setpoint management and rapid response to load changes, enabling tight control of dispense temperatures. Staff can achieve repeatable pour conditions without manual guesswork or frequent adjustments, ensuring a consistent customer experience.
#@@# Compressor Performance#@#
The 1/2 HP compressor paired with R-134a refrigerant delivers 3,600 BTU of cooling capacity while operating on 115v/60/1-ph power. Facilities benefit from robust cooling in a compact footprint, making it suitable for backbars and utility rooms where space is at a premium.
#@@# Electrical Integration#@#
The unit draws 21 amps and ships with a NEMA L5-30P plug for compatible services, supporting straightforward installation into existing commercial electrical arrangements.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect pump seals and hose connections weekly; tighten clamps and replace cracked lines to prevent leakage and pressure loss. Flush glycol bath quarterly and replenish to maintain 11.5 gallons capacity and proper freeze protection; verify concentration with a refractometer. Clean condenser fins monthly to sustain 3,600 BTU heat rejection and ensure airflow. Calibrate the digital thermostat biannually and test compressor current draw to confirm 21 amps operation.