Skip to main content

Micro Matic CDI552-BF 0.31" Inside Dia. Barriermaster Flavorlock Trunk Line

Micro Matic

$22.20
(No reviews yet) Write a Review
SKU:
CDI552-BF
Weight:
0.10 LBS
Shipping:
Calculated at Checkout
Filter Type:
Hoses and Tubings
email_price:
no
Tags:
Beverage Trunk Housing
Label Option type:
rectangles
Net Price:
14.43
msrp_price:
no
Ship From:
34604
Product Taxonomy:
CulinaryDepot>>Commercial Refrigerator>>Refrigeration Parts and Accessories>>Bar Refrigeration Draft Parts and Accessories>>Tap Towers, Faucets, & Faucet Handles
call_price:
no
map_price:
no
Mfr Toll Free:
(866) 327-4159
Packed By:
1 Each
add_to_cart:
no
MAP Price:
22.20
Manufacturer:
Micro Matic
login_price:
no
List Price:
32.07
Trigger BC Integration:
Y-1/13/2026_6:00PM
Taxonomy Weight:
0.1
Filter_Manufacturer:
Micro Matic
Filter_Type:
Hoses and Tubings
Primary Image:
Micro Matic_CDI552-BF.png
specsheet:
Micro Matic_CDI552-BF.pdf
warranty:
Micro Matic_CDI552-BF_1.pdf
manual:
Micro Matic_CDI552-BF_2.pdf
Sale Price:
22.20
Filter_Pro:
yes
PRO:
yes
SKU Number:
CDI552-BF__1152
Keyfeatures5:
Lightweight 0.1 pounds per assembly
Keyfeatures4:
Compatible with Micro Matic draft systems
Keyfeatures6:
Designed for commercial beverage rigs
Keyfeatures:
0.31" inside diameter precision fit
Keyfeatures3:
Flavorlock sealing to reduce flavor transfer
Keyfeatures2:
5/16" I.D. trunk line with glycol pairs
short_description:
Micro Matic cdi552-bf barriermaster flavorlock trunk line features a 0.31" inside diameter with five product lines and two glycol lines for beverage distribution.
Adding to cart… The item has been added
Stop compromising flow for flavor. This trunk line delivers controlled distribution for multi-product draft systems while preserving aroma integrity across extended runs. Designed for commercial tap lines, it supports high-throughput dispensing with consistent performance and simplified serviceability.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug dispensing lines and drain product. Rinse trunk with potable water, then wipe interior with a mild detergent solution. Scrub glycol lines gently; flush with water until clear. Sanitize surfaces with an approved food-contact sanitizer and air dry completely. Inspect seals and fittings for wear and tighten hose clamps. Clean coils and vents monthly to maintain cooling efficiency and reduce fire risk. Record cleaning dates to meet CSA and inspection requirements.#@@#Additional Info#@#Micro Matic's CDI552-BF Barriermaster Flavorlock trunk line has a 0.31" inside diameter and 5/16" I.D. tubing with dual glycol lines, ensuring consistent temperature control and reduced flavor transfer for commercial draft systems.#@@#General Info#@#Description #@# Stop compromising flow for flavor. This trunk line delivers controlled distribution for multi-product draft systems while preserving aroma integrity across extended runs. Designed for commercial tap lines, it supports high-throughput dispensing with consistent performance and simplified serviceability. #@@# Inner Diameter#@# 0.31 inches inside diameter balances flow rate and pressure stability for five product lines. Engineers specify this dimension to maintain consistent pour volumes and reduce foaming in busy service environments. #@@# Product Configuration#@# Five product channels plus two glycol lines allow simultaneous distribution and temperature control for multiple products. Operators gain centralized routing and minimized line crossover, which reduces installation complexity and preserves product separation. #@@# Flavorlock Sealing#@# Flavorlock technology isolates product channels to limit flavor transfer between lines during idle periods. Facilities maintain taste integrity across different ales, lagers, and other offerings, supporting product quality and customer satisfaction. #@@# Glycol Integration#@# Dual glycol lines provide active chilling to the trunk assembly, enabling consistent temperature control along long runs. Technicians achieve precise cooling, which extends shelf life on taps and maintains optimal dispensing temperatures under heavy use. #@@# Durable Construction#@# Materials selected for draft service resist common contaminants and tolerate routine cleaning protocols. Maintenance teams perform scheduled sanitation with minimal material degradation, lowering replacement frequency and operational interruptions. #@@# Compact Footprint#@# A slim trunk profile fits tight backbar and under-counter layouts without sacrificing capacity. Installers position the trunk close to towers and coolers to shorten run lengths, improving thermal stability and reducing refrigerant load. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the Micro Matic CDI552-BF trunk line weekly for signs of wear, kinks, or discoloration and replace compromised sections immediately. Flush lines with approved cleaner after each heavy-use cycle and purge with CO2 to remove residues. Sanitize fittings and glycol lines monthly using manufacturer-recommended solutions and verify seal integrity on all connections. Calibrate flow and pressure while monitoring temperature; document service actions for CSA compliance and traceability.