Stop compromising throughput for consistency. This 60-gallon natural gas mixer kettle delivers strong thermal input and continuous agitation for high-volume cook-chill and batch production in commercial kitchens. Designed for institutional and retail foodservice, it features a horizontal agitator, variable speed control, and a patented gas power burner to ensure uniform product quality across large batches.
LongDescription#@#NA#@@#Cleaning Instructions#@#Turn off gas and cool kettle. Drain fluids and remove cover. Wipe interior liner and agitator with warm, soapy water; rinse and dry. Clean exterior and control panel with non-abrasive cleaner. Flush 3" air piston valve and check low water LED operation. Degrease burner area and vents to prevent fires. Inspect seals and fittings for wear; tighten or replace as needed. Perform coil and valve checks monthly to maintain efficiency and pass inspections.#@@#Additional Info#@#Cleveland's HAMKGL60CC-NG HA Series Mixer Kettle offers a 60 Gal.#@@#General Info#@#Description #@#
Stop compromising throughput for consistency. This 60-gallon natural gas mixer kettle delivers strong thermal input and continuous agitation for high-volume cook-chill and batch production in commercial kitchens. Designed for institutional and retail foodservice, it features a horizontal agitator, variable speed control, and a patented gas power burner to ensure uniform product quality across large batches.
#@@# Large Capacity#@#
Sixty gallons (225 liters) of usable volume support full-scale recipe batching and reduce cycles in high-demand environments. Gallon markings inside the jacket in 10-gallon / 40-liter increments enable precise portioning and consistent scaling for recipe control.
#@@# Agitator Drive#@#
A 3 HP horizontal agitator drive ensures continuous mixing to prevent scorching and maintain uniform product texture during cook and chill processes. Variable speed control lets operators adjust mixing intensity for viscous sauces, soups, and fillings.
#@@# Gas Power Burner#@#
The patented gas power burner delivers responsive thermal input for fast ramp-up and stable temperature hold under load. Natural gas operation with a 50 PSI steam jacket rating ensures efficient heat transfer and minimizes fuel interruptions during busy cycles.
#@@# Controls And Safety#@#
Solid-state temperature controls and a 3" air piston valve provide precise heat modulation and reliable pressure management. A two-piece spring assist cover with a safety screen and a low water LED indicator enhance operator safety and reduce thermal risks.
#@@# Sanitary Construction#@#
The 316 stainless steel liner resists corrosion from acidic formulations and simplifies cleaning to meet institutional sanitation standards. Stationary style with NSF certification supports use in hospitals, schools, and other regulated facilities.
#@@# Service Integration#@#
The unit operates on 208/240 volts, 3-phase electrical service, drawing 15 amps for auxiliary functions.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the Cleveland HAMKGL60CC-NG mixer kettle daily for seal integrity and burner flame stability. Drain and flush the steam jacket monthly to remove sediment and verify 50 PSI rating compliance. Descale the 316 stainless liner quarterly with manufacturer-approved solutions and rinse thoroughly. Lubricate the 3 HP agitator drive per service intervals and test variable speed control. Replace worn gaskets and verify Low Water LED operation before use.