Stop sacrificing control for simplicity. This thermostatic expansion valve precisely manages refrigerant flow to stabilize evaporator superheat and maintain consistent cooling performance in commercial refrigeration systems. Engineers and technicians will appreciate its compact profile, measured tolerances, and compatibility across various installations for predictable operation.
LongDescription#@#NA#@@#Cleaning Instructions#@#Clean high-touch zones like menu covers, shakers, chair backs, and door handles with a hospital-grade disinfectant and microfiber cloth, following label contact time. Use a mild detergent and warm water for vinyl and wood; dry immediately to prevent staining. Empty and vacuum crevices under booths and shelves daily to deter pests. Schedule weekly inspections to ensure surfaces meet CSA and health-code expectations and to preserve furniture life.#@@#Additional Info#@#PartsTown SBFSAAAC TXV expansion valve controls refrigerant flow for precise superheat management in commercial refrigeration systems, measures 5.2" length by 5.1" width and 3.25" height, weighs 1.23 pounds, and carries CSA recognition.#@@#General Info#@#Description #@#
Stop sacrificing control for simplicity. This thermostatic expansion valve precisely manages refrigerant flow to stabilize evaporator superheat and maintain consistent cooling performance in commercial refrigeration systems. Engineers and technicians will appreciate its compact profile, measured tolerances, and compatibility across various installations for predictable operation.
#@@# Thermostatic Control#@#
This valve employs a thermostatic sensing element to regulate refrigerant flow based on evaporator temperature and load. Technicians gain accurate superheat control, reducing liquid carryover and maintaining heat transfer efficiency.
#@@# Compact Dimensions#@#
Measuring 5.2 inches long, 5.1 inches wide, and 3.25 inches high, the valve fits into tight service spaces without modifying existing piping layouts. Installers can minimize cabinet intrusion while retaining access for maintenance and retrofit work.
#@@# Robust Construction#@#
Engineers specify components that withstand continuous duty; this valve weighs 1.23 pounds and uses durable materials to resist vibration and thermal cycling. Maintenance teams will notice fewer mechanical failures and longer service intervals under normal operating conditions.
#@@# Wide Compatibility#@#
Designers will appreciate compatibility with common refrigeration system architectures used in food service, hospitality, and institutional facilities. Service crews can standardize spare parts across multiple assets, simplifying inventory and reducing downtime.
#@@# Precise Flow Regulation#@#
Internal metering provides stable refrigerant modulation to match evaporator load shifts, improving temperature stability in cabinets and process equipment. Operations staff will experience more consistent product temperatures and reduced compressor cycling.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Installers must verify the fit and orientation of the SBFSAAAC TXV EXP VALVE and check compatibility with system pressures before commissioning. Inspect the valve body and connections for debris; flush system lines with the appropriate solvent and trap particulates in a filter. Replace seals and gaskets at the first sign of wear and torque fittings to manufacturer specifications. Calibrate superheat based on load conditions and record settings.