Stop compromising control for convenience. This thermostatic expansion valve delivers precise refrigerant metering at a stable 54 PSI setpoint while allowing on-site adjustment to match system load and operating conditions. Technicians gain faster commissioning and tighter superheat control, reducing duty cycles and improving system responsiveness without the need to replace the valve.
LongDescription#@#NA#@@#Cleaning Instructions#@#Wipe valve exterior with a soft cloth and detergent solution; flush internal passages with clean water after disassembly to remove debris. Use a non-corrosive sanitizer on high-touch surfaces surrounding the unit, then rinse and dry. Inspect fittings and seals for wear; replace damaged parts immediately. Regular cleaning prevents cross-contamination of menus and surfaces, supports health-code compliance, deters pests by removing residues, and preserves valve service life.#@@#Additional Info#@#PartsTown TXV valve DUK216864 regulates refrigerant flow at 54 psi with adjustable setpoint Y1001 and 1/8" capillary connection; compact 6.35" by 3.6", 0.82 pounds, compatible with commercial refrigeration systems for precise temperature control.#@@#General Info#@#Description #@#
Stop compromising control for convenience. This thermostatic expansion valve delivers precise refrigerant metering at a stable 54 PSI setpoint while allowing on-site adjustment to match system load and operating conditions. Technicians gain faster commissioning and tighter superheat control, reducing duty cycles and improving system responsiveness without the need to replace the valve.
#@@# Flow Control#@#
The valve provides modulated refrigerant flow matched to evaporator demand, ensuring consistent evaporator performance. Field adjustment capability allows technicians to fine-tune flow to correct for piping length, charge variance, or load shifts.
#@@# Adjustable Setpoint#@#
Technicians can alter the 54 PSI setpoint within a defined range to optimize superheat for specific system designs. This adjustability minimizes the need for shimming or additional components during retrofit and new-install work.
#@@# Compact Form Factor#@#
The valve measures approximately 6.35 inches in length and 3.6 inches in height, allowing integration into tight rack or unitary assemblies. The compact footprint simplifies routing and reduces the chance of interference with nearby components.
#@@# Durable Construction#@#
Engineers fabricated internal components to withstand typical refrigeration pressures and thermal cycling found in commercial kitchens and light industrial installations. The robust build minimizes service frequency and supports extended operational intervals.
#@@# Serviceability#@#
Field-accessible adjustment and standard connection fittings enable rapid replacement and tuning during maintenance calls. Technicians avoid lengthy downtime and limit the number of on-site parts required for repair.
#@@# Compatibility and Compliance#@#
The valve uses a 1/8-inch connection and conforms to common installation practices, supporting retrofits across a range of commercial refrigeration and cooling systems.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the TXV valve visually and verify model DUK216864 matches system specifications; confirm 54PSI setpoint and 1/8C port orientation. Drain refrigerant per CSA and local code before service. Replace gaskets and O-rings and apply lubricant rated for refrigeration systems. Clean surrounding piping and remove debris to prevent valve clogging. Torque fittings to manufacturer values and pressure-test the circuit. Record service date, adjustments, and parts used for traceability.