Skip to main content

Micro Matic IK-4 0.25" Glycol Cooled Dispense System Installation Kit

Micro Matic

$573.64
(No reviews yet) Write a Review
SKU:
IK-4
Weight:
0.00 LBS
Shipping:
Calculated at Checkout
Filter Type:
Installation Kits
email_price:
no
Tags:
Draft Beer System Parts
Label Option type:
rectangles
Net Price:
506.39
msrp_price:
no
Ship From:
34604
Product Taxonomy:
CulinaryDepot>>Commercial Refrigerator>>Refrigeration Parts and Accessories>>Bar Refrigeration Draft Parts and Accessories>>Tap Towers, Faucets, & Faucet Handles
call_price:
no
map_price:
no
Mfr Toll Free:
(866) 327-4159
Packed By:
1 Each
add_to_cart:
no
MAP Price:
573.64
Manufacturer:
Micro Matic
login_price:
no
List Price:
1125.30
Trigger BC Integration:
Y-6/24/2026_6:00PM
Filter_Type:
Installation Kits
Primary Image:
Micro Matic_IK-4.png
warranty:
Micro Matic_IK-4_1.pdf
manual:
Micro Matic_IK-4_2.pdf
Sale Price:
573.64
Filter_Manufacturer:
Micro Matic
SKU Number:
IK-4__1152
Keyfeatures5:
Python Jacket Tool for installation
Keyfeatures4:
Flavourlock tubing preserves integrity
Keyfeatures:
Glycol-cooled 1/4" dispense kit for temp control
Keyfeatures3:
Stainless fittings reduce contamination
Keyfeatures2:
Includes 20 glycol lines for setup
short_description:
Micro Matic IK-4 glycol-cooled dispense kit includes glycol lines, fittings, clamps, insulation, tubing, clips, and a cutting tool for kegroom setups.
Lead Time:
2 - 3 Business Days
PRO:
yes
Adding to cart… The item has been added
Stop sacrificing draft integrity for convenience. This glycol-cooled dispense system installation kit includes all components needed to build controlled-temperature draft lines, preserving flavor and reducing foam for high-volume operations. Designed for technicians and facilities teams, the kit consolidates fittings, clamps, pre-wrapped glycol lines, and specialized tapes into one package, speeding up installation and standardizing procedures.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug dispense lines and drain glycol before cleaning. Flush lines with warm water, then circulate a food-safe cleaner per manufacturer concentration for 10–15 minutes. Rinse until clear. Wipe exterior fittings, clamps, and tailpieces with a non-abrasive cleaner and soft cloth. Inspect insulation, tapes, and seals; replace damaged components. Dry all parts completely before reassembly. Perform this routine weekly to prevent contamination, fires, and equipment failure.#@@#Additional Info#@#Micro Matic IK-4 Glycol Cooled Dispense System Kit includes glycol lines, tailpieces, clamps, tapes, cutting tool, clips, tubing, restrictors, and instructions for sanitary, temperature-controlled beverage dispensing.#@@#General Info#@#Description #@# Stop sacrificing draft integrity for convenience. This glycol-cooled dispense system installation kit includes all components needed to build controlled-temperature draft lines, preserving flavor and reducing foam for high-volume operations. Designed for technicians and facilities teams, the kit consolidates fittings, clamps, pre-wrapped glycol lines, and specialized tapes into one package, speeding up installation and standardizing procedures. #@@# Complete Line Package#@# The kit provides pre-wrapped glycol lines and tailpieces, splicers, and U-bends to assemble a continuous cooled trunk and tap network. Technicians get materials for consistent thermal performance, reducing sourcing and measurement errors. #@@# Precision Flow Control#@# Spiral restrictors and documentation enable calibrated flow rates for 1/4" ID service lines, ensuring stable pour volumes and less turbulence at the faucet. Operators achieve repeatable dispense characteristics, lowering waste and improving satisfaction. #@@# Thermal Management#@# Foil, foam, and moisture barrier tapes, along with pre-wrapped glycol tubing, deliver layered insulation and vapor protection. Facilities teams maintain glycol loop efficiency, prevent condensate, and preserve insulation R-values and line longevity. #@@# Stainless Hardware#@# 1/4" and 3/8" stainless steel tailpieces and splicers resist corrosion and ensure sanitary fluid pathways in high-use environments. Durable fittings withstand repeated disassembly and cleaning without compromising seals. #@@# Secure Mounting#@# Trunk line mounting clips and stepless clamps simplify routing and strain relief for extended runs through bars, kitchens, and service corridors. Installers reduce line fatigue, minimizing leaks and service needs. #@@# Tooling And Consumables#@# The Python jacket cutting tool and Barrier Master Flavourlock tubing enable quick modifications and flavor-protective line segments during expansion or repair. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Maintain the Micro Matic IK-4 glycol kit by flushing glycol lines weekly with approved solution to prevent biofilm and ensure temperature stability. Inspect clamps, tailpieces, splicers, U-bends, and clips monthly for corrosion or looseness; retorque clamps to specified PSI. Replace foam, foil, and tapes at first sign of wear. Clean Master Flavourlock tubing monthly; document actions for compliance.