Stop sacrificing control for simplicity. This CO2 primary regulator combines precise pressure management with robust construction to support draft systems that require consistent dispense performance and minimal downtime. Operators gain accurate pressure control from 0 to 15 PSI while monitoring source and delivery pressures on dual gauges calibrated for commercial use.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug CO2 lines and vent pressure per Micro Matic instructions before cleaning. Remove the regulator and wipe the exterior with a cloth dampened in mild detergent. Rinse with clean water and dry thoroughly. Inspect gauges, fittings, and seals; replace damaged seals. Clean threads with a soft brush. Reinstall the regulator, leak-test all connections with soap solution, and confirm the 0–15 PSI range. Perform routine checks to prevent contamination, fires, and failures.#@@#Additional Info#@#Micro Matic's 842-15-PP Premium Plus double gauge regulator provides 0–15 PSI CO2 control for draft systems, with dual gauges for pressure monitoring, brass construction, adjustable relief, and CSA compliance.#@@#General Info#@#Description #@#
Stop sacrificing control for simplicity. This CO2 primary regulator combines precise pressure management with robust construction to support draft systems that require consistent dispense performance and minimal downtime. Operators gain accurate pressure control from 0 to 15 PSI while monitoring source and delivery pressures on dual gauges calibrated for commercial use.
#@@# Pressure Range#@#
The unit delivers adjustable output from 0 to 15 PSI, allowing system tuning for a wide range of carbonated products. Technicians achieve consistent pour quality and reduced line foaming by setting pressure within narrow tolerances.
#@@# Dual Gauge Monitoring#@#
Two high-visibility gauges show tank and outlet pressures concurrently, enabling rapid diagnostics during service. Staff reduce troubleshooting time by identifying source depletion or downstream restriction at a glance.
#@@# Durable Construction#@#
Manufacturers designed the housing and fittings for continuous use in backbars and service areas, resisting corrosion and wear. Maintenance teams report longer intervals between replacements thanks to solid materials and precision machined components.
#@@# Flow Capacity#@#
Engineers sized internal passages to support typical draft runs without inducing pressure drop, preserving carbonation levels from storage to tap. Managers maintain consistent product quality across multiple dispense points when systems operate within specified flow limits.
#@@# Safety Features#@#
The regulator includes integrated overpressure protection and secure hose connections to prevent accidental release and ensure compliance with safe gas handling. Safety officers appreciate clear markings and reliable shutoff that minimize risk during cylinder changes.
#@@# Serviceability Design#@#
The assembly allows straightforward gauge replacement and seat servicing with common tools, reducing labor hours for repair.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect regulator fittings and hose connections weekly; tighten threaded joints to 20–25 ft·lb torque where specified and replace O-rings showing wear. Purge trapped moisture by draining inline moisture separators after each 24-hour busy cycle. Clean gauge faces with a soft cloth and isopropyl alcohol; avoid solvents that degrade seals. Calibrate output pressure against a reference gauge quarterly and document readings for CSA compliance records.