Skip to main content

Hatco S-45 16 Gal. Powder-Coated Silver Gray Hammertone Electric Imperial Booster Heater - 208 Volts 3-Ph 45000 Watts

Hatco

$5,261.30
(No reviews yet) Write a Review
SKU:
S-45
Weight:
224.00 LBS
Shipping:
Calculated at Checkout
SKU Number:
S-45__1114
NSF Certified:
Yes
Wattage:
45 Kilowatts
email_price:
no
Tags:
Booster Heater, Electric
Label Option type:
rectangles
Net Price:
4783.00
msrp_price:
no
Ship From:
54235
Product Taxonomy:
CulinaryDepot>>Restaurant Equipment>>Dishwashing Equipment>>Booster Heater
call_price:
no
map_price:
yes
Freight Class:
100
Packed By:
1 Each
add_to_cart:
no
MAP Price:
5261.30
Manufacturer:
Hatco
login_price:
no
List Price:
9566.00
Trigger BC Integration:
Y-1/6/2026_6:15PM
Made in USA:
Yes
Capacity:
16 Gal.
Taxonomy Weight:
224
Amps:
125
cULus Certified:
Yes
Phase:
3-Ph
Hertz:
60
Filter_Manufacturer:
Hatco
Filter_Power Type:
Electric
Filter_Watts:
40 - 57 Kilowatts
Filter_Voltage:
208 Volts
Primary Image:
Hatco_S-45.png
specsheet:
Hatco_S-45.pdf
warranty:
Hatco_S-45_1.pdf
Sale Price:
5261.30
Voltage:
208v
Filter_Made in America:
Yes
Power Type:
Electric
Filter_Pro:
yes
PRO:
yes
Filter_NSF Listed:
Yes
732 Location Available:
0
Keyfeatures5:
Powder-coated finish resists corrosion
Keyfeatures4:
NSF and cULus certified for safety
Keyfeatures6:
Made in USA for dependable service
Keyfeatures:
16 gallons storage for continuous wash cycles
Keyfeatures3:
208 volts, 3-Ph for commercial systems
Keyfeatures2:
45,000 Watts heating for rapid recovery
short_description:
Hatco s-45 booster heater offers 16 gallons of insulated storage with a Castone® lined tank and stainless steel front, designed for high-demand dishroom use and certified by NSF and CSA.
Lead Time:
2 - 4 Business Days
Adding to cart… The item has been added
Stop sacrificing recovery time for throughput. This electric booster heater delivers high-temperature rinse recovery and consistent output for continuous dishroom cycles, providing crews with the heat capacity they need without process disruption. Designed for institutional and commercial kitchens, this unit combines robust electrical performance with certified safety features to support heavy-duty wash operations.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug the unit and lock out power at the breaker before servicing. Drain the 16 gallons and remove access panels. Flush the Castone® lined tank with potable water, then scrub surfaces with a mild alkaline cleaner to remove scale and grease. Rinse thoroughly and inspect heating elements, coils, and seals; replace worn gaskets. Clean exterior with non-abrasive cloth. Verify voltage at 208v and phase connectors, then restore power and monitor for leaks and correct temperature.#@@#Additional Info#@#Hatco S-45 Electric Imperial booster heater stores 16 gallons and delivers 45 kW at 208 volts, 3-phase. It produces 45,000 watts and 125 amps for quick sanitizing.#@@#General Info#@#Description #@# Stop sacrificing recovery time for throughput. This electric booster heater delivers high-temperature rinse recovery and consistent output for continuous dishroom cycles, providing crews with the heat capacity they need without process disruption. Designed for institutional and commercial kitchens, this unit combines robust electrical performance with certified safety features to support heavy-duty wash operations. #@@# Power Capacity#@# This heater supplies 45 kilowatts at 208 volts, 3-Ph, enabling rapid temperature rise and steady rinse delivery under sustained load. Facilities expecting long service periods will benefit from predictable thermal performance and reduced cycle interruptions. #@@# Tank Volume#@# This model stores 16 gallons of hot water to sustain high-volume rinsing sequences during peak hours. Operators will minimize downtime between cycles and maintain required rinse temperatures for compliance and wash quality. #@@# Construction Quality#@# This unit features a stainless steel front and a Castone lined tank with a powder-coated silver gray hammertone finish for corrosion resistance and simplified cleaning. Maintenance teams will perform routine service with less effort, and external surfaces resist scuffs and chemical exposure. #@@# Certification Compliance#@# This booster meets NSF and cULus standards and comes from domestic manufacture, supporting safety inspections and procurement policies that prioritize certified equipment. Procurement officers will document regulatory alignment and simplify acceptance testing. #@@# Electrical Performance#@# The heater draws 125 amps at 60 hertz and integrates into three-phase 208v electrical systems to deliver reliable power distribution. Electric kitchens and large facilities will achieve stable operation with balanced load sharing and clear electrical specifications. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Service teams should inspect heating elements monthly and replace any that show corrosion or uneven scaling. Clean the Castone® lined tank quarterly by draining, flushing with potable water, and removing sediment with a nonscratch brush. Verify electrical connections each month, tighten terminals to specified torque, and confirm 208v 3-Ph supply and 125 amp protection. Lubricate accessible valves annually and test safety controls after maintenance.