This electrical heated air door offers continuous protection for large openings while maintaining indoor temperature stability and reducing infiltration losses. Designed for facility managers and operations teams, it combines industrial performance with serviceable components to support demanding installations.
LongDescription#@#NA#@@#Cleaning Instructions#@#Wipe high-touch zones (menu covers, shakers, chair backs, door handles) with EPA-approved disinfectant and a microfiber cloth. Clean non-food surfaces daily; scrub crevices and under booths weekly to remove crumbs and grease. Rinse surfaces that contact food after sanitizing. Inspect and tighten fittings monthly. Regular cleaning prevents germ transfer, deters pests, preserves furnishings, and supports health-code compliance.#@@#Additional Info#@#Berner ARC16-2120E-3 is a 120" heated recessed air door with 16 air velocity for openings up to 16 ft, 480 volts 3-Ph, 28 kW, two 1 HP motors, and two-speed control via Intelliswitch; cULus certified, hinged access panel, made in USA, 317 pounds.#@@#General Info#@#Description #@#
This electrical heated air door offers continuous protection for large openings while maintaining indoor temperature stability and reducing infiltration losses. Designed for facility managers and operations teams, it combines industrial performance with serviceable components to support demanding installations.
Two 1 HP motors deliver staged airflow so operators can match output to occupancy and weather conditions. Installers find two-speed control simplifies commissioning while managers gain operating flexibility to reduce energy use during off-peak hours.
480 volts three-phase power supplies robust, continuous operation for long runs and heavy-duty applications. Engineers benefit from steady electrical input that supports the unit’s 28 kW heating element without frequent fault trips.
An Intelliswitch controller provides programmable sequencing and simplified field tuning for consistent performance. Technicians access diagnostics and mode selection to optimize runtime and ensure reliable service intervals.
A recessed mounting profile integrates into ceilings and headers for a low-visibility installation in premium environments. Architects and facility teams preserve aesthetic goals while achieving effective air separation for openings up to 16 feet high.
Hinged white aluminum bottom access panel permits fast field service and component replacement without removing the assembly. Maintenance crews reduce downtime because routine checks and motor access occur from the occupied side.
cULus certification validates compliance with North American electrical and safety standards, and manufacturing in the USA supports regional sourcing requirements. Procurement professionals receive clear documentation for code review and lifecycle planning.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect intake and discharge grills weekly; remove debris and vacuum coils to maintain airflow. Lubricate motor bearings as per manufacturer intervals and check tightness of electrical connections on the 480 volts 3-Ph supply. Test heating elements under load and confirm Intelliswitch controller responses in two-speed operation. Replace worn gaskets on the hinged aluminum access panel and tighten mounting hardware for installations up to 16 Ft.