Stop compromising air control for design. This recessed air door delivers concentrated airflow and precise installation for high-traffic openings, supporting consistent interior conditions without exposing mounting hardware. Food service managers and facilities teams will appreciate the engineered balance of airflow, serviceability, and electrical compatibility for three-phase systems.
LongDescription#@#NA#@@#Cleaning Instructions#@#Wipe exterior surfaces and high-touch zones—menu covers, chair backs, handles, shakers—using a mild detergent solution and a microfiber cloth; apply EPA-registered sanitizer where required and follow dwell time. Remove crumbs and debris from booth crevices and under shelving to deter pests. Inspect for residue weekly and deep-clean monthly. Regular cleaning prevents contamination of clean items and hands, supports health-code compliance, and preserves furnishings' condition.#@@#Additional Info#@#Berner ARC16-2120A-3 is a 120" un-heated recessed air door for commercial entrances. It features two 1 HP motors, two-speed operation, Intelliswitch control, and a hinged white aluminum access panel.#@@#General Info#@#Description #@#
Stop compromising air control for design. This recessed air door delivers concentrated airflow and precise installation for high-traffic openings, supporting consistent interior conditions without exposing mounting hardware. Food service managers and facilities teams will appreciate the engineered balance of airflow, serviceability, and electrical compatibility for three-phase systems.
#@@# Motor Redundancy#@#
Two 1 HP motors supply independent drive to maintain airflow if one motor requires service, improving uptime in continuous operations. Maintenance teams will find access straightforward thanks to the hinged white aluminum bottom access panel that permits rapid inspection and repair.
#@@# Two Speed Control#@#
An integrated two-speed configuration provides operational flexibility to match traffic patterns and seasonality, reducing energy use during low-demand periods. Staff can select high output for peak hours and switch to lower airflow to minimize draft and noise during off-peak shifts.
#@@# Intelliswitch Controller#@#
The Intelliswitch controller delivers reliable motor coordination and simple user interaction, allowing technicians to set controls without complex programming. Facilities managers gain predictable performance and repeatable response across multiple installations.
#@@# Recessed Architectural Fit#@#
Designed for recessed installation, the unit integrates into ceilings and headers to preserve clean visual lines while protecting components from tampering. Architects and operations directors achieve a discreet installation for openings up to 16 feet high without sacrificing functional coverage.
#@@# 480 Volt Three Phase#@#
The 480 volts, 3-Ph electrical configuration aligns with commercial power infrastructure, enabling efficient distribution for large installations and minimizing circuit loading. Electricians will appreciate that the unit meets cULus certification for safety and code compliance.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the air door monthly and tighten hardware to prevent vibration and airflow loss. Clean inlet screens and fan blades with compressed air or a soft brush to remove dust; disconnect power at the CSA-compliant disconnect before servicing. Lubricate motor bearings per manufacturer intervals using recommended lubricant and ensure both 1 HP motors spin freely on both speeds. Replace damaged seals and ensure the white aluminum access panel closes flush.