Stop compromising on entry control or climate separation. This electric heated air door delivers targeted airflow and thermal protection for large openings, combining two high-torque motors, a variable speed controller, and heavy-duty construction to maintain conditioned space, reduce infiltration, and support energy management in demanding commercial settings.
LongDescription#@#NA#@@#Cleaning Instructions#@#Wipe high-touch surfaces (menu covers, shakers, chair backs, door handles) with a detergent solution, then apply an EPA-registered sanitizer per label. Clean non-food-contact areas (shelves, booth crevices, floor edges) daily to remove crumbs and grease. Use soft cloths for wood and vinyl; avoid abrasives on metal. Inspect and tighten hardware weekly. Regular cleaning prevents germ transfer, deters pests, preserves furnishings, and supports health-code compliance.#@@#Additional Info#@#Berner ARC16-2060E-2-3 is a 60" heated recessed air door with two 1 HP motors, two-speed operation, and an Intelliswitch controller for heights up to 16 ft. It operates at 208 volts, 3-Ph, draws 28 kW, is cULus certified, and ships made in USA.#@@#General Info#@#Description #@#
Stop compromising on entry control or climate separation. This electric heated air door delivers targeted airflow and thermal protection for large openings, combining two high-torque motors, a variable speed controller, and heavy-duty construction to maintain conditioned space, reduce infiltration, and support energy management in demanding commercial settings.
#@@# Motor Redundancy#@#
Two 1 HP motors drive this unit, providing redundancy and sustained airflow for openings up to 16 feet. The system can maintain performance if one motor requires service, reducing the risk of abrupt capacity loss during peak operation.
#@@# Dual Speed Control#@#
The two-speed design pairs with an Intelliswitch controller to match airflow to traffic patterns and heating demands. Operators can reduce noise and energy use during low traffic while ramping output when demand increases, thus improving operational efficiency.
#@@# Electric Heat Output#@#
The unit supplies 28 kW of electric heat at 208 volts three-phase to reinforce the air barrier and limit cold drafts across the entire 60-inch span. Facilities that require consistent thermal separation will benefit from steady, evenly distributed heated airflow.
#@@# Architectural Recessed Design#@#
A recessed configuration integrates into ceiling or header spaces to preserve sight lines and maintain aesthetic continuity in lobbies or commercial entrances. Installers gain easier concealment without sacrificing service access through the hinged bottom panel.
#@@# Service Access Panel#@#
The hinged white aluminum bottom access panel opens for fast on-site maintenance and motor servicing, minimizing downtime. Technicians can reach internal components without removing the housing, which accelerates routine inspections and repairs.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the ARC16-2060E-2-3 air door monthly and remove dust from intake and discharge grilles to maintain airflow. Tighten mounting hardware and verify the hinged white aluminum bottom access panel secures properly. Lubricate motor bearings per manufacturer intervals and test both 1 HP motors at low and high speeds. Confirm Intelliswitch controller functions and verify voltage at 208 volts, phase 3-Ph. Replace worn seals and verify cULus label visibility.