Stop sacrificing entrance control for energy loss and inconsistent airflow. This heated recessed air door combines targeted thermal delivery with a controlled 16-foot coverage height to reduce infiltration and maintain conditioned zones in high-traffic openings. Designed for commercial facilities, the unit balances throughput, safety, and uptime for facility managers and food service operators.
LongDescription#@#NA#@@#Cleaning Instructions#@#Wipe exterior surfaces and high-touch zones with a EPA-registered disinfectant; follow label dwell time and use a microfiber cloth. Vacuum intake grille and remove debris monthly; inspect motor and access panel screws quarterly and tighten if needed. Clean condensate pans and drain paths to deter pests and corrosion. Regular cleaning prevents contamination transfer to staff and customers, supports health-code compliance, and preserves finish and function of the air door.#@@#Additional Info#@#Berner ARC16-1060E-2-3 is a 60" heated recessed air door for heights up to 16 ft. It runs on 208 volts, 3-Ph, with a 1 HP motor, 14 kW heat, Intelliswitch controller, and a hinged aluminum access panel. It meets cULus standards and weighs 171 pounds.#@@#General Info#@#Description #@#
Stop sacrificing entrance control for energy loss and inconsistent airflow. This heated recessed air door combines targeted thermal delivery with a controlled 16-foot coverage height to reduce infiltration and maintain conditioned zones in high-traffic openings. Designed for commercial facilities, the unit balances throughput, safety, and uptime for facility managers and food service operators.
#@@# Motor Configuration#@#
The assembly includes a single 1 HP motor that delivers dependable push through a two-speed design, enabling operators to select higher airflow during peak entry or lower flow for quieter times. Selectable speeds reduce energy draw when full capacity proves unnecessary while preserving core air separation performance.
#@@# Electric Heat Output#@#
The unit provides 14 kW of electric heat at 208 volts, three-phase input, offering rapid thermal compensation for open doors in cold conditions. Electric heating removes combustion risks and simplifies installation where gas service lacks availability or where code restricts fuel-fired devices.
#@@# Mounting and Coverage#@#
Engineers specify this recessed model for mounting heights up to 16 feet, making it suitable for standard industrial and institutional openings. The 60-inch length covers common door widths while the architectural profile integrates flush into ceiling or header assemblies.
#@@# Control Interface#@#
An Intelliswitch controller gives operators precise runtime and mode selection, improving responsiveness to changing traffic patterns and ambient conditions. Configurable control logic minimizes operator intervention and supports predictable thermal management strategies.
#@@# Service Access#@#
A hinged white aluminum bottom access panel allows rapid access to electrical connections and internal components, shortening service intervals and reducing downtime. Field technicians perform routine checks and adjustments without disassembling structural elements.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the air curtain monthly for dust on intake grilles and fan blades; remove power and vacuum or brush components to maintain airflow. Verify electrical connections quarterly, tighten loose lugs to manufacturer torque values, and confirm 208 volts supply and 3-Ph balance under load. Lubricate motor bearings per Berner schedule, replace filters if pressure drop exceeds limits, and test Intelliswitch control functions.