Skip to main content

Unox XAPHA-HC23 21.12" W Steam Condensation Hood with Catalysts Activated Carbons Filter Ventless Hood - 208-240 Volts

Unox

$2,496.00
(No reviews yet) Write a Review
SKU:
XAPHA-HC23
Weight:
35.20 LBS
Shipping:
Calculated at Checkout
SKU Number:
XAPHA-HC23__779
Voltage:
208/240v
email_price:
No
Tags:
Ventless Exhaust System
Label Option type:
rectangles
Net Price:
1971.06
msrp_price:
No
Ship From:
28037
Product Taxonomy:
CulinaryDepot>>Restaurant Equipment>>Commercial Oven>>Commercial Oven Parts & Accessories>>Convection Oven Parts & Accessories
Keyfeatures5:
Lightweight 35.2 pounds for easy install
call_price:
yes
map_price:
No
Packed By:
1 Each
Keyfeatures4:
700 Watts for efficient steam condensation
MAP Price:
2496
Keyfeatures6:
Low energy consumption
Manufacturer:
Unox
login_price:
No
Keyfeatures:
Ventless hood with activated carbon filter for odor control
Keyfeatures3:
Compact 21.12" W saves space
Keyfeatures2:
Designed for 208-240v, 1-Ph, 60 Hz
List Price:
3120.00
Trigger BC Integration:
Y-6/17/2026_6:00PM
Taxonomy Weight:
35.2
Phase:
1-Ph
Hertz:
60
Filter_Manufacturer:
Unox
Primary Image:
Unox_XAPHA-HC23.png
Sale Price:
2496
short_description:
Unox xapha-hc23 steam condensation hood with catalysts and activated carbon filters offers ventless exhaust for commercial ovens, designed for 21.12" width and 700 watts.
Lead Time:
1-3 Business Days
Real Weight:
57.3
Real Width:
40.9
Real Depth:
29.5
is free shipping:
Yes
Adding to cart… The item has been added
Stop sacrificing hood performance for installation limits. This steam condensation hood mounts compactly at 21.12 inches to control steam and odors without a remote exhaust connection, offering ventless operation suited for kitchens constrained by ductwork and regulatory limits. The unit runs on 208-240v single-phase power and delivers engineered air treatment for high-turnover cooking environments.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug the unit and let it cool. Remove filters; wash catalysts and carbon housings with mild detergent and warm water, then rinse and air dry. Vacuum vents and wipe stainless surfaces with a non-abrasive cleaner. Clean the condensate tray and drain lines to avoid clogs. Inspect seals and replace worn gaskets. Reinstall dry filters and reconnect power.#@@#Additional Info#@#Unox XAPHA-HC23 steam condensation ventless hood measures 21.12" W by 8.68" H with a 29.18" depth.#@@#General Info#@#Description #@# Stop sacrificing hood performance for installation limits. This steam condensation hood mounts compactly at 21.12 inches to control steam and odors without a remote exhaust connection, offering ventless operation suited for kitchens constrained by ductwork and regulatory limits. The unit runs on 208-240v single-phase power and delivers engineered air treatment for high-turnover cooking environments. #@@# Compact Footprint#@# This hood measures 21.12 inches wide and installs where wall or shelf space restricts larger systems, enabling tight kitchen layouts to retain full combi oven capability. Designers can place the hood directly above small to medium combi units without extensive remodeling. #@@# Power Requirements#@# The assembly operates on 208-240v, 60 Hz, 1-Ph electrical supply and consumes 700 Watts, allowing predictable circuit planning for commercial installations. Technicians can size breakers and wiring with standard single-phase specifications to reduce installation time. #@@# Filtration System#@# The hood integrates catalysts and activated carbon filtration to neutralize odors and capture condensate from steam generation, reducing the need for external exhaust. Operators notice reduced smell transfer to adjacent service areas and simplified compliance with indoor air expectations. #@@# Ventless Operation#@# This ventless design eliminates the need for rooftop ducts and external fans, letting kitchens relocate equipment without structural exhaust modification. Facility managers avoid costly ventilation runs and preserve rooftop integrity while maintaining code-conscious indoor air handling. #@@# Thermal Management#@# The condensation mechanism captures steam and cools exhaust internally, minimizing moisture deposition on surrounding surfaces and protecting nearby equipment. Maintenance teams experience less corrosion and fewer moisture-related service calls. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#Ensure proper electrical connection and ventilation setup before installation.#@@#Maintenance Guide#@#Maintain the Unox XAPHA-HC23 ventless hood by inspecting catalysts and activated carbon filters monthly and replacing per manufacturer intervals. Clean condensate channels with neutral detergent and flush with warm water to prevent buildup. Verify electrical connections at 208-240v, 60 Hz, 1-Ph are secure and torque to spec. Remove debris from inlet screens weekly. Record service dates and filter changes to ensure compliant operation and predictable performance.