Skip to main content

True TD-50-18-HC 49.5" W Black Flat Top Bottle Cooler - 115V

true

$2,630.65
(No reviews yet) Write a Review
SKU:
TD-50-18-HC
Weight:
275.00 LBS
Shipping:
Calculated at Checkout
SKU Number:
TD-50-18-HC__1304
etllisted:
TRUE
Barrel Style:
Barrel Lock Standard
Compressor HP:
1/5 HP
Cord Length:
7
Exterior Finish:
Black
Interior Finish:
Galvanized
Lid:
2
Lids:
2
Nema Plug Type:
NEMA 5-15P
Refrigerant Type:
R-290
Refrigeration Location:
Side Mounted
Temperature (Refrigerator ):
33°F to 38°F
Voltage:
115v
Width (side - side):
37 - 50"
email_price:
no
Tags:
Bottle Cooler
Label Option type:
rectangles
Net Price:
2618.05
msrp_price:
no
Ship From:
63366
Product Taxonomy:
CulinaryDepot>>Restaurant Equipment>>Beverage Equipment>>Bar Refrigeration>>Bottle Coolers
call_price:
no
map_price:
yes
Freight Class:
150
Packed By:
1 each
add_to_cart:
no
MAP Price:
2630.65
Manufacturer:
true
login_price:
No
Product ID:
ea148ceb-c10d-dd11-a23a-00304834a8c9
List Price:
8705
Trigger BC Integration:
Y-7/6/2026_6:00PM
UL Certified:
Yes
Taxonomy Weight:
275
Amps:
1.9
Phase:
1-Ph
Hertz:
60
Filter_Cord Length:
7
Filter_Manufacturer:
True
Filter_Capacity:
21 - 40
Filter_Voltage:
115 Volts
Filter_Plug Type:
NEMA 5-15P
Filter_Phase:
1
Filter_Weight:
275
Filter_Exterior Finish:
Black
Filter_Made in America:
Yes
Filter_Depth:
21 - 40 Inches
Filter_Width:
41 - 60 Inches
Filter_Height:
21 - 40 Inches
Filter_Amps:
1.9 Amps
Primary Image:
True_TD-50-18-HC.png
specsheet:
True_TD-50-18-HC.pdf
Sale Price:
2630.65
is free shipping:
Yes
Keyfeatures5:
Holds 21–40 bottles per unit
Keyfeatures4:
Operates on 115 volts with NEMA 5-15P plug
Keyfeatures6:
Made in USA with UL and CSA certifications
Keyfeatures:
Commercial-grade black exterior for durability
Keyfeatures3:
R-290 refrigerant for efficient cooling
Keyfeatures2:
49.5" width fits standard back bars
short_description:
True td-50-18-hc black flat top bottle cooler measures 49.5" wide, providing durable cold storage for high-volume beverage service.
Made in USA:
Yes
cULus Certified:
Yes
Filter_Refrigerant Type:
R-290
732 Location Available:
0
UL EPH Classified:
Yes
Lead Time:
1-2 Business Days
PRO:
yes
has video:
LSO5jYhgEzs
Adding to cart… The item has been added
Stop settling for inadequate cold storage. This 49.5-inch flat top bottle cooler ensures consistent temperature control and high capacity for busy bars, cafeterias, and catering operations, allowing staff to serve chilled bottles without the need for frequent restocking. Operators will appreciate its durable construction and efficient cooling, which support continuous service in commercial environments.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug the unit and remove bottles. Mix mild detergent with warm water (use gallons or liters as needed) and scrub interior with a soft cloth. Rinse and dry all surfaces thoroughly. Clean condenser coils with a brush every month to maintain efficiency and lower energy use. Degrease vents and lids to reduce fire risk. Inspect door gaskets for wear and replace when cracked. Regular cleaning removes bacteria, prevents fires, cuts utility costs, and helps pass CSA and health inspections.#@@#Additional Info#@#The True TD-50-18-HC 49.5" W black flat top bottle cooler runs on 115 volts, 1.9 amps, and R-290 refrigerant. It supports two lids and has a 275-pound chassis with CSA and UL certifications, NEMA 5-15P cord, and is U.S. made.#@@#General Info#@#Description #@# Stop settling for inadequate cold storage. This 49.5-inch flat top bottle cooler ensures consistent temperature control and high capacity for busy bars, cafeterias, and catering operations, allowing staff to serve chilled bottles without the need for frequent restocking. Operators will appreciate its durable construction and efficient cooling, which support continuous service in commercial environments. #@@# Capacity Optimization#@# Designed to accommodate 21 to 40 cases depending on configuration, this cooler offers substantial inventory space while maintaining a compact depth of 26.88 inches. Managers can stage service items on top while accessing chilled stock through two lids, reducing trip time and enhancing throughput. #@@# Efficient Electrical Design#@# Engineered for 115 volts operation with a 7-foot cord and NEMA 5-15P plug, the unit integrates seamlessly with standard kitchen circuits and draws 1.9 amps. Technicians will value the single-phase power and 60 hertz compatibility, which simplify installation and ensure predictable energy consumption. #@@# Low Global Warming Refrigerant#@# Utilizing R-290 refrigerant, this cooler delivers effective cooling with a lower environmental impact compared to older refrigerants. Service teams will find a reduced regulatory burden and maintenance parity with modern commercial refrigeration systems. #@@# Robust Construction#@# Finished in black with a reinforced flat top, the cabinet withstands daily wear in high-traffic settings and supports preparation tasks on its surface. Operators will notice a sturdy feel under load and consistent alignment of lids during repetitive use. #@@# Safety and Certification#@# Meets ETL, UL, and cUL certification standards and indicates CSA compliance where applicable, ensuring adherence to commercial safety requirements. Procurement leads and facility managers can be confident that the unit meets inspection and code expectations. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#Upon confirmation of completed payment, Culinary Depot will ship/deliver the True TD-50-18-HC Bottle Cooler.#@@#Maintenance Guide#@#Service teams should inspect condenser coils monthly and remove dust with a soft brush or vacuum. Use mild detergent and warm water to clean surfaces; rinse and dry shelves before returning them to service. Check door gaskets for cracks and replace if compression fails. Level the unit and confirm 115v supply and NEMA 5-15P connection to prevent electrical stress. Monitor refrigerant R-290 lines for leaks and schedule annual CSA or cULus safety checks.