Skip to main content

Town 244255-3 Universal Burner Orifice

Town

$27.23
(No reviews yet) Write a Review
SKU:
244255-3
Weight:
0.40 LBS
Shipping:
Calculated at Checkout
SKU Number:
244255-3__1300
email_price:
no
Tags:
Chinese Pork Roaster/Smoker Parts
Label Option type:
rectangles
Net Price:
22.50
msrp_price:
no
Ship From:
11222
Product Taxonomy:
CulinaryDepot>>Restaurant Equipment>>Commercial Oven>>Commercial Oven Parts & Accessories>>Smoker Parts and Accessories
call_price:
no
map_price:
no
Mfr Toll Free:
(800) 221-5032
Freight Class:
85
add_to_cart:
no
MAP Price:
27.23
Manufacturer:
Town
login_price:
no
List Price:
56.25
Taxonomy Weight:
0.4
Filter_Manufacturer:
Town
Trigger BC Integration:
Y-5/13/2026_6:00PM
Primary Image:
Town_244255-3.png
Sale Price:
27.23
Filter Type:
Orifices
Filter_Type:
Orifices
Keyfeatures4:
Compatible with Town commercial smoker and roaster parts
Keyfeatures:
Universal burner orifice kit fits SM-24 for easy replacement
Keyfeatures3:
Reduces downtime for foodservice operations
Keyfeatures2:
Includes three precision orifices for consistent gas flow
short_description:
Optimize burner performance with the Town 244255-3 universal burner orifice set, featuring three precision-matched orifices for SM-24 smokers. Technicians install the 0.4-pound kit quickly to restore gas flow and maintain CSA compliance.
Lead Time:
2 - 3 Business Days
Packed By:
1 each
Adding to cart… The item has been added
Stop compromising precision for compatibility. This universal burner orifice kit supplies three matched orifices engineered to restore consistent gas flow and repeatable flame profiles across commercial smokers and roasters, enabling technicians to return equipment to service quickly. Foodservice teams gain a compact parts solution that simplifies inventory and reduces downtime for kitchen operations.
LongDescription#@#NA#@@#Cleaning Instructions#@#Remove burners and cool unit before cleaning. Use a mild detergent and warm water; soak orifices briefly, brush deposits with a soft-bristle brush, then rinse and air dry. Inspect ports for clogging and pierce blockages with a non-magnetic wire if needed. Reinstall parts and test flame pattern; adjust or replace if irregular. Clean surrounding grease traps and vents weekly to reduce fire risk, bacterial growth, and equipment wear. Follow CSA and manufacturer guidelines for safe operation.#@@#Additional Info#@#Town 244255-3 Universal Burner Orifice set includes three precision orifices for SM-24 burners, each 3" deep and 0.4 pounds, ensuring consistent gas flow; CSA-compliant design aids maintenance for restaurants, hospitals, and catering facilities.#@@#General Info#@#Description #@# Stop compromising precision for compatibility. This universal burner orifice kit supplies three matched orifices engineered to restore consistent gas flow and repeatable flame profiles across commercial smokers and roasters, enabling technicians to return equipment to service quickly. Foodservice teams gain a compact parts solution that simplifies inventory and reduces downtime for kitchen operations. #@@# Orifice Match#@# Each kit contains three orifices sized for universal fit applications, delivering consistent gas metering for appliances that require replacement parts. Technicians obtain uniform flow characteristics that stabilize combustion and reduce flame variation across multiple burners. #@@# Flow Calibration#@# Manufactured tolerances maintain predictable orifice diameter and port geometry, ensuring repeatable volumetric flow at specified inlet pressures. Engineers achieve reliable heat output that supports even cooking and controlled smoke generation in Chinese pork roasters and similar units. #@@# Compact Pack#@# The design groups three pieces into a single pack that reduces procurement complexity for maintenance departments and spare parts inventories. Facilities managers minimize stock variants while keeping essential replacement components on hand. #@@# Durable Construction#@# Town produces these orifices using corrosion-resistant materials suitable for commercial kitchen environments, sustaining performance under repeated thermal cycles. Service teams experience fewer premature replacements and maintain functional integrity in demanding schedules. #@@# Simple Installation#@# Each orifice adapts to standard burner ports and installs with basic field tools, enabling line technicians to complete swaps rapidly during scheduled service windows. Operations regain full burner function without extended labor or specialized tooling. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the burner orifices monthly and remove debris with a soft-bristled brush to maintain consistent flame characteristics. Replace the three-piece set if threads show wear or if flow varies beyond specification. Verify alignment and torque during reassembly to prevent gas leaks; apply a leak-detection solution to joints and tighten fittings as required. Document service dates and parts installed for CSA compliance and warranty tracking.