For commercial kitchens that require precise hot-water control, this thermostatic mixing valve ensures consistent outlet temperatures and reliable safety performance. Installers will appreciate the 1/2" NPT connections that seamlessly integrate with standard plumbing layouts, while facility managers benefit from a compact, serviceable design engineered for continuous use in institutional and foodservice environments. The valve effectively reduces scald risk by maintaining setpoints under varying inlet conditions, supporting compliance efforts in hospitals, schools, and hospitality operations.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug connected water supply. Shut main valve, relieve pressure, then remove the T&S Brass EC-SMT thermostatic mixing valve per manufacturer torque specs. Soak valve parts in mild detergent solution, brush debris from screens and seats, rinse with clean water, and inspect seals for wear. Reassemble with new gaskets if needed and test at 1/2" NPT connections for leaks and correct temperature. Clean monthly to prevent bacteria, fires, higher bills, equipment failure, and inspection failures.#@@#Additional Info#@#T&S Brass EC-SMT 1/2" NPT Thermostatic Mixing Valve delivers temperature-controlled water for hands-free faucets in commercial kitchens and healthcare.#@@#General Info#@#Description #@#
For commercial kitchens that require precise hot-water control, this thermostatic mixing valve ensures consistent outlet temperatures and reliable safety performance. Installers will appreciate the 1/2" NPT connections that seamlessly integrate with standard plumbing layouts, while facility managers benefit from a compact, serviceable design engineered for continuous use in institutional and foodservice environments. The valve effectively reduces scald risk by maintaining setpoints under varying inlet conditions, supporting compliance efforts in hospitals, schools, and hospitality operations.
#@@# Valve Accuracy#@#
The valve maintains a stable mixed temperature through an internal thermostatic element that reacts to inlet fluctuations, ensuring consistent output even when supply pressures vary. Operators can expect repeatable setpoints that protect end users and prevent product loss from thermal inconsistencies.
#@@# Serviceability Design#@#
Technicians can access replaceable internal components without removing the body from the line, which reduces downtime during maintenance. This service-friendly layout shortens repair times and lowers labor costs for routine part replacement.
#@@# Compact Footprint#@#
The valve occupies minimal space, allowing installation in tight cabinet risers, under sinks, or within equipment chaseways commonly found in restaurants and hospitals. Its compact sizing enables retrofits where larger mixing assemblies would not fit.
#@@# Material Durability#@#
Manufactured with corrosion-resistant materials suited for commercial plumbing, the valve withstands repeated thermal cycles and common water chemistries found in institutional settings. Its robust construction extends component life and reduces the frequency of replacement.
#@@# Safety Compliance#@#
The unit meets relevant safety expectations for thermostatic mixing devices used in public and clinical facilities, delivering controlled hot-water delivery that minimizes scald incidents.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Maintain the T&S Brass EC-SMT 1/2" NPT thermostatic mixing valve by inspecting inlet strainers monthly and flushing debris to preserve flow. Verify temperature setpoint quarterly using a calibrated thermometer and adjust per manufacturer instructions. Lubricate O-rings annually with silicone-compatible lubricant and replace seals when wear appears. Confirm tightness of NPT connections after service and test operation under full hot and cold supply pressures to ensure stable mixed output.