Skip to main content

T&S Brass B-0965 Atmospheric Vacuum Breaker Assembly

T&S Brass

Was: $132.66
Now: $126.26
(No reviews yet) Write a Review
SKU:
B-0965
Weight:
1.46 LBS
Shipping:
Calculated at Checkout
SKU Number:
B-0965__1284
IPS:
1/2"
email_price:
no
Tags:
Vacuum Breaker Assembly
Label Option type:
rectangles
Net Price:
111.29
msrp_price:
no
Product Taxonomy:
CulinaryDepot>>Restaurant Equipment>>Restaurant Faucet and Plumbing>>Faucet, Sink, & Drain Accessories>>Faucet Parts and Accessories>>Breakers, Valves & Preventers
call_price:
no
map_price:
yes
Freight Class:
77.5
add_to_cart:
yes
MAP Price:
132.66
Manufacturer:
T&S Brass
login_price:
yes
Product ID:
9437e4a3-c10d-dd11-a23a-00304834a8c9
List Price:
247.30
Trigger BC Integration:
Y-6/24/2026_6:00PM
Taxonomy Weight:
1.46
Primary Image:
B-0965.jpg
Sale Price:
126.26
Item Type:
Vacuum Breaker Assembly
specsheet:
T&S Brass_B-0965.pdf
Filter Type:
Assemblies
Filter_Manufacturer:
T&S Brass
Filter_Type:
Assemblies
Keyfeatures5:
Lightweight 1.46 pounds reduces strain
Keyfeatures4:
CSA-compliant components for code adherence
Keyfeatures6:
Prevents backflow for safe water supply
Keyfeatures:
Durable atmospheric vacuum breaker for potable lines
Keyfeatures3:
Corrosion-resistant brass body for longevity
Keyfeatures2:
Compact 1/2" IPS connection for easy installation
short_description:
T&S Brass B-0965 vacuum breaker prevents backflow contamination in plumbing systems, fitting 1/2" connections and weighing 1.46 pounds.
Lead Time:
2 - 3 Business Days
Ship From:
29690
Allow to show add to cart:
Login or Add to Cart to See Price
Real Weight:
1.46
Real Width:
9.5
Real Height:
3.5
Real Depth:
8.5
Dimensions:
8.5 9.5 3.5
PRO:
yes
Adding to cart… The item has been added
For commercial plumbing systems that require reliable backflow prevention, this atmospheric vacuum breaker assembly provides strong protection and easy installation. It effectively prevents siphonage and safeguards potable water lines in foodservice and institutional facilities where intermittent backflow risks are present. The assembly meets industry standards for durability and ensures consistent performance in high-use sink and faucet installations.
LongDescription#@#NA#@@#Cleaning Instructions#@#Turn off water and relieve pressure. Remove the T&S Brass B-0965 Atmospheric Vacuum Breaker Assembly from the line. Soak parts in warm, mild soap solution and scrub with a soft brush. Rinse with clean water and inspect seals for wear; replace damaged seals. Reassemble and test for leaks at 1/2" connection. Clean monthly or after heavy use to prevent contamination, fires from grease buildup, higher utility bills, and equipment failure.#@@#Additional Info#@#T&S Brass B-0965 Vacuum Breaker Assembly prevents backflow contamination by interrupting siphonage. The 1/2" IPS unit installs inline, weighs 1.46 pounds, and meets plumbing standards for restaurants and hospitality.#@@#General Info#@#Description #@# For commercial plumbing systems that require reliable backflow prevention, this atmospheric vacuum breaker assembly provides strong protection and easy installation. It effectively prevents siphonage and safeguards potable water lines in foodservice and institutional facilities where intermittent backflow risks are present. The assembly meets industry standards for durability and ensures consistent performance in high-use sink and faucet installations. #@@# Construction Materials#@# The unit is made from corrosion-resistant brass components designed to endure continuous exposure to water and cleaning agents commonly found in kitchens, hospitals, and cafeterias. Its solid-body construction minimizes the risk of leaks and reduces maintenance intervals for facility engineers. #@@# Flow Capacity#@# Designed for 1/2" connections, the assembly offers sufficient flow characteristics for standard handwash and prep faucets in restaurants, bars, and school kitchens. Technicians can integrate it without upsizing supply lines, maintaining system hydraulics and peak flow rates. #@@# Backflow Prevention#@# The atmospheric vacuum breaker prevents back-siphonage by opening to atmospheric pressure under negative inlet conditions, ensuring the integrity of potable water. Facilities managers benefit from passive protection that does not require external power or active controls. #@@# Serviceability#@# The assembly features serviceable internals for in-field inspection and part replacement, which reduces downtime during routine maintenance. Maintenance staff can quickly replace seals and springs without removing the entire assembly from the line. #@@# Compliance Profile#@# Engineered to comply with common plumbing codes for vacuum breaker applications, the device supports regulatory compliance for foodservice and institutional installations. Documentation and part traceability simplify recordkeeping for audits and health inspections. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the T&S Brass B-0965 Atmospheric Vacuum Breaker Assembly monthly for mineral buildup and corrosion. Remove the unit and flush with potable water; soak in a 1:10 vinegar-to-water solution for ten minutes to dissolve deposits. Replace worn seals and O-rings annually or when leakage appears. Lubricate moving parts with NSF-approved silicone grease. Record maintenance dates and serial references to ensure regulatory compliance.