Skip to main content

RedGoat RAC2-10H RAC2 Disposer Control Panel

RedGoat

$2,685.90
(No reviews yet) Write a Review
SKU:
RAC2-10H
Weight:
25.00 LBS
Shipping:
Calculated at Checkout
SKU Number:
RAC2-10H__1242
email_price:
no
Tags:
Disposer Control Panel
Label Option type:
rectangles
Net Price:
2417.31
msrp_price:
no
Ship From:
17601
Product Taxonomy:
CulinaryDepot>>Shop By Brand>>RedGoat>>RedGoat Garbage Disposers Parts & Accessories
call_price:
no
map_price:
no
Mfr Toll Free:
(800) 237-6628
Vendor:
1242
Freight Class:
UPS
add_to_cart:
no
MAP Price:
2685.90
Manufacturer:
RedGoat
login_price:
no
Product ID:
3546c182-c10d-dd11-a23a-00304834a8c9
List Price:
3837.00
Trigger BC Integration:
Y-6/19/2026_1:05PM
Capacity:
1
Primary Image:
RedGoat_RAC2-10H.png
Sale Price:
2685.90
specsheet:
RedGoat_RAC2-10H.pdf
warranty:
RedGoat_RAC2-10H_1.pdf
Voltage:
480v
Phase:
1-Ph
Taxonomy Weight:
25
Filter Type:
Controls
Packed By:
1 Each
Filter_Manufacturer:
RedGoat
Filter_Type:
Controls
cULus Certified:
Yes
732 Location Available:
0
Keyfeatures5:
cULus certified for safety
Keyfeatures4:
NEMA 4X watertight fiberglass reinforced enclosure
Keyfeatures:
Auto-reversing magnetic controls prevent jams
Keyfeatures3:
Front-mounted illuminated start/stop buttons
Keyfeatures2:
Built-in automatic reset overload relays ensure uptime
short_description:
RedGoat RAC2-10H disposer control panel features auto-reversing magnetic controls, automatic reset overload relays, indicator lights, and illuminated start/stop buttons for 10 HP disposers.
Lead Time:
2 - 3 Business Days
is free shipping:
Yes
PRO:
yes
Adding to cart… The item has been added
Stop sacrificing uptime for control. This industrial control panel delivers precise motor management for 10 HP disposers on 440-480V/60/3-phase systems while protecting circuits and simplifying operator interaction. Designed for heavy use in commercial kitchens and institutional facilities, the unit combines robust electrical protection with intuitive front-mounted controls for consistent, predictable operation.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug power and lock out circuits before servicing the RedGoat RAC2-10H disposer control panel. Wear gloves and eye protection. Remove dust with a dry brush; clean enclosure with a damp cloth and mild detergent, then dry thoroughly. Inspect indicator lights, pushbuttons, disconnect switch, and overload relays for damage. Verify NEMA 4X seals intact. Test start/stop operation and auto-reverse function at 480v after restoring power and removing lockout.#@@#Additional Info#@#RedGoat's RAC2-10H control panel offers auto-reversing magnetic controls for 10 HP disposers (440-480v/60/3-ph), with automatic reset overload relays, illuminated buttons, indicator lights, a front disconnect switch, and a NEMA 4X enclosure.#@@#General Info#@#Description #@# Stop sacrificing uptime for control. This industrial control panel delivers precise motor management for 10 HP disposers on 440-480V/60/3-phase systems while protecting circuits and simplifying operator interaction. Designed for heavy use in commercial kitchens and institutional facilities, the unit combines robust electrical protection with intuitive front-mounted controls for consistent, predictable operation. #@@# Enclosed Controls#@# The unit houses auto-reversing magnetic controls that manage motor direction and protect against jamming, ensuring continuous throughput in high-demand settings. Technicians can access all components inside a NEMA 4X watertight fiberglass reinforced polyester enclosure that resists moisture and corrosion. #@@# Operator Interface#@# Front-mounted illuminated start/stop pushbuttons provide visible status and straightforward operation for line staff and facilities teams. Indicator lights communicate run, fault, and reset conditions at a glance, reducing troubleshooting time. #@@# Overload Protection#@# Built-in automatic reset overload relays monitor current draw and reset after fault clearance to minimize downtime and avoid unnecessary manual intervention. Facilities managers can rely on consistent protection that reduces nuisance trips while guarding motors against thermal damage. #@@# Disconnect Safety#@# An integrated disconnect switch isolates the control circuit for service and maintenance, meeting common safety procedures for commercial installations. Electricians can perform lockout-tagout work with a clearly defined isolation point that improves compliance and technician safety. #@@# Electrical Compatibility#@# Engineered for 440-480V/60/3-phase applications, the panel supports 10 HP disposer motors and aligns with standard commercial power infrastructure. Project planners find the voltage and phase rating straightforward for integration into existing three-phase distributions. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect electrical connections monthly and tighten screws to prevent arcing and nuisance tripping. Cycle start/stop pushbuttons weekly to confirm operation and clean contacts with approved cleaner. Verify indicator lights and reset overload relays during every service. Maintain gasket integrity and clean NEMA 4X fiberglass surfaces with mild detergent; avoid solvents that degrade seals. Record all tests and replacements for CSA compliance.