Skip to main content

RATIONAL 60.76.179 UltraVent Recirculating Condensation Hood For Electric Combi-Duo Stacked Units SelfCookingCenter 61 SelfCookingCenter 101 CombiMaster Plus 61 Or CombiMaster Plus 120 Volts

RATIONAL

$5,265.60
(No reviews yet) Write a Review
SKU:
60.74.973
Weight:
154.00 LBS
Shipping:
Calculated at Checkout
SKU Number:
60.76.179__1240
Voltage:
120v
email_price:
no
Tags:
Ventless Exhaust System
Label Option type:
rectangles
Net Price:
3824.14
msrp_price:
no
Ship From:
60008
Product Taxonomy:
CulinaryDepot>>Restaurant Equipment>>Dishwashing Equipment>>Condensate Hoods
call_price:
no
map_price:
yes
Mfr Toll Free:
(888) 320-7274
Freight Class:
85
Packed By:
1 each
add_to_cart:
no
MAP Price:
5265.60
Manufacturer:
RATIONAL
login_price:
no
Product ID:
5941c02d-58a1-4999-9599-903e7eb1acd8
List Price:
6582.00
Trigger BC Integration:
Y-6/23/2026_6:00PM
UL Certified:
Yes
Taxonomy Weight:
154
Amps:
3.6 Amps
Phase:
1
Hertz:
60
Filter_Manufacturer:
RATIONAL
Filter_Depth:
45 - 56 Inches
Filter_Width:
33 - 42 Inches
Primary Image:
RATIONAL_60.74.973.png
specsheet:
RATIONAL_60.74.973.pdf
Sale Price:
5265.60
Item Type:
Condensate Hoods
warranty:
RATIONAL_60.74.973_1.pdf
Keyfeatures5:
Compact: 33.63" W x 38.38" D
Keyfeatures4:
Operates on 120v, 3.6 Amps, 60 Hz
Keyfeatures:
Ventless exhaust design for kitchens
Keyfeatures3:
Compatible with SelfCookingCenter and CombiMaster
Keyfeatures2:
CSA certified for compliance
short_description:
Rational 60.76.179 ultravent hood mounts above electric combi-duo units to capture steam from SelfCookingCenter and CombiMaster Plus units.
732 Location Available:
0
CSA Certified:
Yes
Keyfeatures6:
NEMA 5-15P plug for easy installation
Lead Time:
1 Business Day
is free shipping:
Yes
PRO:
yes
Adding to cart… The item has been added
Stop sacrificing kitchen workflow for code compliance. This recirculating condensation hood combines engineered exhaust control with compact dimensions, allowing stacked electric combi ovens to operate without a conventional duct run. This design maintains kitchen layout flexibility and regulatory adherence while eliminating the need for rooftop infrastructure.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug the unit and allow 10 minutes to cool. Remove filters and wash with warm, soapy water; rinse and air dry. Wipe interior and exterior panels using a non-abrasive detergent and soft cloth. Clean condensate tray and drain with a brush to remove grease and debris. Inspect seals and vents; clear obstructions. Reinstall components, restore power, and run a test cycle. Regular cleaning prevents contamination, fires, inefficiency, and equipment failure.#@@#Additional Info#@#RATIONAL UltraVent model 60.76.179 fits stacked electric Combi-Duo units like SelfCookingCenter 61/101 and CombiMaster Plus 61/120. It operates on 120v, draws 3.6 Amps, and measures 33.63" wide, 38.38" deep, and 17.75" high.#@@#General Info#@#Description #@# Stop sacrificing kitchen workflow for code compliance. This recirculating condensation hood combines engineered exhaust control with compact dimensions, allowing stacked electric combi ovens to operate without a conventional duct run. This design maintains kitchen layout flexibility and regulatory adherence while eliminating the need for rooftop infrastructure. #@@# Dimensions And Fit#@# Select this hood when vertical space and footprint determine installation viability. The unit measures 33.63 inches wide, 38.38 inches deep, and 17.75 inches high, allowing direct integration with stacked combi units such as the SelfCookingCenter 61 and 101 or CombiMaster Plus 61 and 120. Installers benefit from the predictable footprint for planning counter clearance and service access. #@@# Recirculation Filtration#@# Trust the engineered condensation management system to process exhaust internally and return treated air to the kitchen. Integrated filtration captures condensate and particulates, reducing the need for external venting while supporting indoor air quality parameters required for ventless systems. Facilities maintain operational continuity where ductwork is impractical. #@@# Electrical And Power#@# Operate the hood from standard 120v power with a single-phase 60 Hz supply, drawing 3.6 Amps and terminating to a NEMA 5-15P connection for simplified electrical hookup. Technicians appreciate compatibility with common branch circuits, reducing electrical labor and speeding up commissioning. Predictable power characteristics assist facilities with budgeting and load calculations. #@@# Regulatory Compliance#@# Rely on documented certifications to meet inspection criteria in ventless installations. The unit carries CSA certification and meets UL standards where applicable, providing the necessary paperwork that inspectors request during permitting and final sign-off. Administrators gain confidence from conformance to established safety and performance benchmarks. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#Upon confirmation of completed payment, Culinary Depot will ship/deliver the RATIONAL 60.76.179 UltraVent Ventless Recirculating Condensation Hood.#@@#Maintenance Guide#@#Inspect the RATIONAL UltraVent condensation hood weekly and remove debris from the intake and recirculation filters to maintain airflow. Drain and sanitize condensate collection trays with a mild detergent and potable water; rinse thoroughly and dry before reinstallation. Verify electrical connections at 120v, 3.6 Amps and confirm NEMA 5-15P plug integrity. Lubricate fan motor bearings quarterly per manufacturer intervals and replace worn seals to prevent leaks and corrosion.