The X20028ABB contactor delivers reliable 16 amp switching at up to 600 VAC, engineered for commercial kitchen equipment controls and industrial power circuits; compact dimensions and straightforward electrical ratings let technicians integrate it into control panels and replace worn relay units with minimal downtime. The 16 Amp Capacity
This contactor supports 16 amps of continuous switching current at 600 VAC, assuring compatibility with a range of medium-duty loads in foodservice and facility equipment; technicians can size control circuits confidently when specifying replacements or upgrades. Compact Profile
Measuring approximately 2.2 inches by 1.9 inches, the contactor’s small footprint simplifies installation inside tight control cabinets or retrofit spaces, reducing the need to reconfigure surrounding components and preserving existing wiring runs. High-Voltage Rating
Rated for 600 VAC operation, the unit handles elevated line voltages commonly found in commercial kitchens and institutional equipment, enabling safe switching of multi-phase or higher-voltage circuits without overstressing contacts. Low Mass
Weighing about 0.38 pounds, the contactor contributes minimal mechanical load on mounting hardware and terminal blocks, which eases handling during service and minimizes strain on supporting brackets in stacked assemblies. Manufacturer Support
Produced by PartsTown under part number GLOX20028ABB, the contactor aligns with industry replacement part conventions, allowing procurement teams to match OEM service schedules and maintain consistent spare-part inventories without compatibility guesswork. Simple Specification
Labeled with a clear catalog identifier and concise electrical specifications, the unit reduces the chance of ordering errors and accelerates maintenance planning by providing the essential technical data technicians need for quick verification and field installation.
LongDescription#@#NA#@@#Cleaning Instructions#@#Wipe surfaces with mild detergent and warm water, focusing on high-touch areas like menu covers, shakers, chairs, and handles to prevent germs. Use a microfiber cloth and change solutions often to avoid contamination. Sanitize visibly for health code compliance. Remove crumbs under shelves and booths to deter pests. Dry wooden or vinyl surfaces after cleaning to preserve finishes.#@@#Additional Info#@#The X20028ABB contactor (GLOX20028ABB) provides 16 amp switching at 600 VAC for commercial equipment control. It measures 2.2" by 2.2" by 1.9" and weighs 0.38 pounds, enabling compact integration into electrical panels and service assemblies.#@@#General Info#@#Description #@#
The X20028ABB contactor delivers reliable 16 amp switching at up to 600 VAC, engineered for commercial kitchen equipment controls and industrial power circuits; compact dimensions and straightforward electrical ratings let technicians integrate it into control panels and replace worn relay units with minimal downtime. The 16 Amp Capacity
This contactor supports 16 amps of continuous switching current at 600 VAC, assuring compatibility with a range of medium-duty loads in foodservice and facility equipment; technicians can size control circuits confidently when specifying replacements or upgrades. Compact Profile
Measuring approximately 2.2 inches by 1.9 inches, the contactor’s small footprint simplifies installation inside tight control cabinets or retrofit spaces, reducing the need to reconfigure surrounding components and preserving existing wiring runs. High-Voltage Rating
Rated for 600 VAC operation, the unit handles elevated line voltages commonly found in commercial kitchens and institutional equipment, enabling safe switching of multi-phase or higher-voltage circuits without overstressing contacts. Low Mass
Weighing about 0.38 pounds, the contactor contributes minimal mechanical load on mounting hardware and terminal blocks, which eases handling during service and minimizes strain on supporting brackets in stacked assemblies. Manufacturer Support
Produced by PartsTown under part number GLOX20028ABB, the contactor aligns with industry replacement part conventions, allowing procurement teams to match OEM service schedules and maintain consistent spare-part inventories without compatibility guesswork. Simple Specification
Labeled with a clear catalog identifier and concise electrical specifications, the unit reduces the chance of ordering errors and accelerates maintenance planning by providing the essential technical data technicians need for quick verification and field installation.#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Disconnect power before servicing the X20028ABB contactor. Inspect terminals for corrosion or looseness; tighten screws to spec. Clean coil and contact faces with compressed air or a soft brush. Check coil resistance and continuity with a multimeter; replace if readings are off. Lubricate moving parts lightly with non-conductive lubricant. Ensure mounting hardware is secure to avoid vibration wear.