Skip to main content

FK07302 BOILER BASE GLASS WATER GAUGE

PartsTown

$49.65
(No reviews yet) Write a Review
SKU:
FK07302
Weight:
0.17 LBS
Shipping:
Calculated at Checkout
Length:
7.35
Label Option type:
rectangles
Net Price:
33.10
Product Taxonomy:
CulinaryDepot>>Parts
Manufacturer:
PartsTown
List Price:
47.96
Trigger BC Integration:
Y-6/2/2026_6:00PM
Taxonomy Weight:
0.17
email_price:
no
msrp_price:
no
call_price:
no
map_price:
no
add_to_cart:
no
MAP Price:
49.65
login_price:
no
Primary Image:
PartsTown_FK07302.png
Sale Price:
49.65
Ship From:
60101
Keyfeatures5:
CSA-compliant for regulatory confidence
Keyfeatures4:
2.15-inch height and width compact
Keyfeatures6:
Manufacturer PartsTown OEM part CLEFK07302
Keyfeatures:
7.35-inch length fits standard mounts
Keyfeatures3:
0.17 pounds lightweight for handling
Keyfeatures2:
Glass gauge ensures direct water reading
short_description:
PartsTown fk07302 boiler base glass water gauge fits boiler assemblies to monitor water levels. The 7.35" long, 2.15" wide, 2.15" high gauge weighs 0.17 pounds and meets CSA component standards.
Lead Time:
2 - 3 Business Days
Adding to cart… The item has been added
Stop compromising clarity for durability. This boiler base glass water gauge delivers precise, continuous visual monitoring of water level inside steam boilers, enabling operators to maintain safe fill conditions and consistent steam production with minimal intervention. Technical personnel and facilities managers will appreciate a straightforward assembly that integrates with existing boiler fittings and provides reliable service life under routine maintenance schedules.
LongDescription#@#NA#@@#Cleaning Instructions#@#Clean the FK07302 boiler base glass water gauge after each shift to prevent contamination of menus, handles, and hands. Use a soft cloth with mild detergent, rinse with water, then wipe dry. Disinfect high-touch zones with an EPA-registered sanitizer per label, allow required contact time, and ventilate area. Inspect seals and glass for cracks; replace damaged units immediately to ensure compliance with CSA and health codes and to reduce pest attraction and material deterioration.#@@#Additional Info#@#PartsTown FK07302 boiler base glass water gauge offers 7.35" length and ASTM-compatible glass for water-level monitoring in steam boilers. It weighs 0.17 pounds and fits 2.15" square mounting; CSA-compliant for commercial foodservice safety.#@@#General Info#@#Description #@# Stop compromising clarity for durability. This boiler base glass water gauge delivers precise, continuous visual monitoring of water level inside steam boilers, enabling operators to maintain safe fill conditions and consistent steam production with minimal intervention. Technical personnel and facilities managers will appreciate a straightforward assembly that integrates with existing boiler fittings and provides reliable service life under routine maintenance schedules. #@@# Glass Gauge#@# Clear borosilicate glass offers direct sight of water level for immediate verification. Operators read levels at a glance, reducing reliance on indirect sensors and minimizing risk of overfill or dry firing. #@@# Protective Shield#@# A metal shield surrounds the tube to reduce exposure to accidental impact and thermal stress. Maintenance teams find it easier to inspect the sight tube while the shield preserves glass integrity during routine access. #@@# Mounting Base#@# Precision-machined base dimensions of 7.35 inches in length and 2.15 inches in width and height ensure accurate alignment with standard boiler flanges. Technicians achieve repeatable installation torque and consistent sealing when replacing legacy components. #@@# Weight Specification#@# At 0.17 pounds, the unit provides low added mass on the boiler face, limiting strain on mounting hardware. Field crews notice easier handling during installation and reduced risk of misalignment caused by heavy replacement parts. #@@# Compliance Marking#@# Unit ships with CSA-compatible materials and manufacturing traceability that align with commercial boiler maintenance protocols. Plant engineers confirm documentation for safety audits and equipment records without extended qualification steps. #@@# Service Life#@# Simple construction reduces failure modes and facilitates inspection intervals common in institutional and commercial kitchens. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect FK07302 BOILER BASE GLASS WATER GAUGE weekly to verify clear sightlines and correct liquid level. Drain and flush the gauge under controlled shutdown to remove sediment; follow lockout procedures and use protective eyewear. Tighten fittings to 10–15 ft·lb torque where applicable and replace worn gaskets with CSA-listed parts. Clean glass with non-abrasive cleaner and lint-free cloth. Record maintenance actions and part numbers for traceability and inventory control.