Skip to main content

33812-6 TC,TYPE "J" SHIELDED 12.00X120

PartsTown

$166.98
(No reviews yet) Write a Review
SKU:
33812-6
Weight:
0.65 LBS
Shipping:
Calculated at Checkout
Length:
16.7
Label Option type:
rectangles
Net Price:
111.32
Product Taxonomy:
CulinaryDepot>>Parts
Manufacturer:
PartsTown
List Price:
152.48
Taxonomy Weight:
0.65
email_price:
no
msrp_price:
no
call_price:
no
map_price:
no
add_to_cart:
no
MAP Price:
166.98
login_price:
no
Trigger BC Integration:
Y-7/16/2026_5:20PM
Primary Image:
PartsTown_33812-6.png
Sale Price:
166.98
Ship From:
60101
Keyfeatures5:
Lightweight 0.65 pounds component weight
Keyfeatures4:
Compact 16.7 mm overall length dimension
Keyfeatures6:
Designed for culinary equipment diagnostics
Keyfeatures:
Shielded Type J thermocouple element
Keyfeatures3:
Compatible with PartsTown replacement parts
Keyfeatures2:
12.00 x 120 mm sensing length
short_description:
The 33812-6 TC, Type "J" shielded 12.00x120 probe by PartsTown ensures precise temperature sensing. MD33812-6 is compact at 16.7" length, 9.85" width, 1.05" height, and 0.65 lbs.
Lead Time:
2 - 3 Business Days
Adding to cart… The item has been added
Built for inline temperature sensing in commercial equipment, this shielded Type J thermocouple provides reliable readings and installs where abrasion and heat protection are needed. It combines a 12.00 x 120 sensor element with a rugged shield, ensuring measurement integrity in confined or high-exposure areas. Its compact size simplifies retrofits and replacements in kitchen appliances and HVAC systems.
LongDescription#@#NA#@@#Cleaning Instructions#@#Wipe high-touch items—menu covers, shakers, chair backs, and door handles—daily with a mild detergent, then sanitize with an EPA-approved disinfectant following label dwell time. Clean non-food-contact surfaces like walls, shelving, and booth crevices to remove crumbs and grease to deter pests and prevent contamination reaching food prep areas. Dry surfaces thoroughly and schedule routine deep cleans to maintain appearance, meet health code expectations, and protect guests and staff.#@@#Additional Info#@#PartsTown MD33812-6 Type J shielded thermocouple measures 12.00 x 120, weighs 0.65 pounds, and fits applications needing precise temperature sensing. Length: 16.7 inches; diameter: 9.85 x 1.05 inches for commercial equipment integration.#@@#General Info#@#Description #@# Built for inline temperature sensing in commercial equipment, this shielded Type J thermocouple provides reliable readings and installs where abrasion and heat protection are needed. It combines a 12.00 x 120 sensor element with a rugged shield, ensuring measurement integrity in confined or high-exposure areas. Its compact size simplifies retrofits and replacements in kitchen appliances and HVAC systems. #@@# Shielded Probe#@# The external shield protects the junction from mechanical damage and heat spikes, preserving accuracy under repeated use. This reduces service frequency and ensures consistent temperature control in production environments. #@@# Type J Sensor#@# The iron-constantan thermocouple alloy offers predictable voltage-to-temperature response across the typical operational range for foodservice equipment. Type J characteristics are ideal for systems calibrated to this sensor family. #@@# Compact Profile#@# With dimensions of 12.00 x 120, the probe fits into narrow wells and tight spaces without disrupting airflow or spacing. Installers benefit from easy routing and stable positioning during equipment operation. #@@# Standard Connector#@# The thermocouple features a conventional tip and lead configuration compatible with common control modules and data systems. Maintenance staff can replace units quickly, reducing downtime during peak service. #@@# Durable Construction#@# Designed for commercial kitchens, the assembly resists wear from vibration and thermal cycling while maintaining signal fidelity. Operators experience fewer false readings and longer intervals between replacements. #@@# Service Availability#@# With multiple units and a manufacturer part number, facilities can standardize spare stock to match equipment needs. This streamlines inventory and reduces repair lead times. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Address the reader formally and follow these procedures to ensure safety and functionality. Clean the Type J thermocouple externally with a soft cloth and mild detergent; avoid immersion. Check the sheath for damage and replace if shielding is compromised. Tighten mounting hardware to specified torque. Calibrate periodically with a traceable reference. Store unused units in a dry, controlled environment.