Stop compromising system stability for short-term fixes. This thermostatic expansion valve delivers precise refrigerant control for R-404A systems, ensuring consistent evaporator performance and predictable temperature regulation. Installers and service technicians will appreciate straightforward sizing and robust construction that reduce downtime and simplify maintenance.
LongDescription#@#NA#@@#Cleaning Instructions#@#Wipe valve exterior and surrounding surfaces with a detergent solution, then rinse and dry with a lint-free cloth. Apply EPA-registered sanitizer on high-touch zones like handles and nearby menu holders; follow dwell times. Inspect seals and fittings for residue; remove deposits with a non-abrasive brush. Dispose of cleaning waste per local code. Regular cleaning prevents contamination transfer, supports inspections, deters pests, and preserves component finish and function.#@@#Additional Info#@#PartsTown TR325-60080-30 thermostatic expansion valve, model AN1/8SW35, supports R-404A/LT refrigerants. It weighs 0.85 pounds, measures 5.25"×4.45"×2.3", and ensures precise refrigerant metering for commercial refrigeration systems.#@@#General Info#@#Description #@#
Stop compromising system stability for short-term fixes. This thermostatic expansion valve delivers precise refrigerant control for R-404A systems, ensuring consistent evaporator performance and predictable temperature regulation. Installers and service technicians will appreciate straightforward sizing and robust construction that reduce downtime and simplify maintenance.
#@@# Flow Control#@#
Engineered to meter refrigerant at a calibrated rate, the valve maintains stable superheat across varying load conditions. Technicians will achieve consistent evaporator performance and reduce the risk of liquid floodback, improving system reliability and extending component lifespan.
#@@# Connection Compatibility#@#
Designed with AN1/8 and 1/4 connections, the valve integrates seamlessly with common refrigeration plumbing, minimizing adaptation time during retrofits. Field crews will save installation hours by matching existing line sizes without the need for custom fittings.
#@@# Refrigerant Specification#@#
Rated specifically for R-404A, the valve aligns with fluid properties to ensure accurate thermal response and control precision. Service teams will achieve correct charge behavior and maintain system efficiency under typical commercial cooling loads.
#@@# Compact Dimensions#@#
Measuring approximately 5.25 inches long, 4.45 inches wide, and 2.3 inches high, the valve fits into tight service spaces within condensing units and reach-in systems. Designers can specify the component in compact assemblies without sacrificing access for adjustments.
#@@# Durable Construction#@#
Weighing about 0.85 pounds, the component utilizes materials that withstand cycling stresses and pressure differentials common in commercial refrigeration. Maintenance crews will experience fewer failures and longer intervals between replacements, effectively lowering lifecycle costs.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the TR325-60080-30 expansion valve weekly for oil traces and frost to detect leaks early. Clean nearby filters and strainers monthly to maintain unrestricted refrigerant flow. Verify torque on fittings and tighten to manufacturer specs after any servicing. Measure superheat and adjust the valve to achieve target values for R-404A/LT; record readings in service logs. Replace the unit if corrosion or internal blockage reduces flow beyond acceptable limits.