Stop compromising system control for simplicity. This thermal expansion valve delivers precise refrigerant metering and robust compatibility for R-404A and mixed-temperature systems, supporting reliable refrigeration performance in high-demand commercial applications. Customers gain a component engineered for accurate superheat control, reducing temperature fluctuations and protecting compressors under variable loads.
LongDescription#@#NA#@@#Cleaning Instructions#@#Wipe valve and surrounding surfaces daily with a mild detergent and a microfibre cloth. Rinse with clean water, dry with lint-free towel, and inspect for corrosion or loose fittings. Sanitize high-touch zones like handles and nearby panels using an EPA-registered sanitizer per label dwell time. Vacuum debris under equipment and remove spills immediately to deter pests and prevent cross-contamination of clean items and hands. Keep maintenance records for inspections.#@@#Additional Info#@#PartsTown TR325-60080-08 thermostatic expansion valve fits R-404A systems, accepts 1/8" sensing bulb and 1/4" connections, controls refrigerant flow, weighs 0.91 pounds, and measures 8" by 2.85" for compact integration.#@@#General Info#@#Description #@#
Stop compromising system control for simplicity. This thermal expansion valve delivers precise refrigerant metering and robust compatibility for R-404A and mixed-temperature systems, supporting reliable refrigeration performance in high-demand commercial applications. Customers gain a component engineered for accurate superheat control, reducing temperature fluctuations and protecting compressors under variable loads.
#@@# Thermostatic Control#@#
This valve provides responsive thermostatic modulation that maintains stable evaporator superheat across changing loads. Technicians achieve tighter temperature control and reduce compressor cycling by stabilizing refrigerant flow at the evaporator inlet.
#@@# Standard Connection#@#
The unit features 1/8-inch sensing and 1/4-inch inlet/outlet fittings that align with common refrigeration piping. Installers save time during retrofits and service calls because the dimensions match prevailing commercial refrigeration practice.
#@@# R-404A Compatibility#@#
Designed for R-404A and medium-temperature applications, the valve supports systems that require this refrigerant blend. Operators maintain system efficiency and avoid performance loss when servicing equipment specified for that refrigerant.
#@@# Compact Footprint#@#
The valve measures approximately eight units in length with a height near 2.85 units, yielding a compact profile for tight mechanical rooms and crowded evaporator assemblies. Engineers gain flexibility when routing refrigerant lines and positioning control elements.
#@@# Durable Construction#@#
Manufactured with service environments in mind, the component weighs approximately 0.91 pounds and resists common service wear. Maintenance teams experience fewer premature failures and lower part replacement frequency when using a robust control element.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Apply inspection every 3 months to the TR325-60080-08 expansion valve to ensure refrigerant flow and prevent performance loss. Check external fittings for leaks with electronic detection and tighten connections to torque specs. Replace filter driers when indicators show contamination. Flush liquid and suction lines before installing a new valve to remove debris. Calibrate superheat per system design; document readings. Lubricate moving linkage with compressor-compatible oil.