Stop sacrificing control for compatibility. This replacement main burner orifice for natural gas restores precise fuel flow to commercial ranges and cooktops, enabling consistent flame intensity and repeatable cooking results. Technicians can install the component quickly, returning equipment to service with minimal downtime and predictable thermal output.
LongDescription#@#NA#@@#Cleaning Instructions#@#Clean high-touch zones like menu covers, shakers, chair backs, and door handles daily to prevent germ transfer and contamination. Use a mild detergent and warm water; apply with a microfiber cloth, scrub visible grime, then rinse and dry. Sanitize with an approved surface sanitizer per label contact time. Inspect under booths and around service stations weekly to deter pests and protect furnishings. Record cleaning steps and times for CSA and inspection compliance.#@@#Additional Info#@#PartsTown MON1044-8 orifice fits natural gas burners with a 0.95" length and 0.5" width, ensuring reliable ignition in commercial ranges; it weighs 0.03 pounds, meets CSA tolerances, and restores accurate BTU delivery for foodservice.#@@#General Info#@#Description #@#
Stop sacrificing control for compatibility. This replacement main burner orifice for natural gas restores precise fuel flow to commercial ranges and cooktops, enabling consistent flame intensity and repeatable cooking results. Technicians can install the component quickly, returning equipment to service with minimal downtime and predictable thermal output.
#@@# Orifice Size#@#
The 0.95 length specification delivers a calibrated flow profile that matches factory performance for natural gas systems. Service technicians can rely on this dimension to maintain correct pressure-to-flow ratios and stable flame geometry during high-demand cycles.
#@@# Flow Accuracy#@#
Manufactured to tight tolerances, the component ensures consistent gas metering across repeated cycles, reducing variance in burner output. Kitchen staff gain predictable heat transfer, improving batch-to-batch consistency for searing, boiling, and simmering tasks.
#@@# Material Weight#@#
At approximately 0.03 pounds, the lightweight construction simplifies handling during replacement and minimizes stress on valve fittings. Installers appreciate the reduced risk of over-torquing and the ease of aligning the orifice within confined burner assemblies.
#@@# Compatibility Fit#@#
Design dimensions of 0.5 width and 0.95 height match common commercial burner interfaces, enabling broad compatibility with multiple range models. Maintenance teams benefit from a straightforward drop-in part that eliminates custom machining or adapter requirements.
#@@# Regulatory Marking#@#
The part carries CSA-relevant manufacturing controls and documentation to support code compliance in many institutional kitchens. Facilities managers receive verifiable traceability for inspections and asset records.
#@@# Service Availability#@#
PartsTown supplies this replacement with a clear manufacturer part number to streamline ordering and inventory management.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the 1044-8 orifice and surrounding manifold monthly for carbon buildup and corrosion; remove deposits with a brass brush and low-pressure air to preserve port geometry. Calibrate gas pressure per manufacturer specs and verify natural gas flow with a manometer. Replace gaskets and seals at first sign of cracking. Lubricate valve linkages lightly with high-temperature grease. Log maintenance actions and parts replaced for CSA compliance and inventory control.