Skip to main content

08-6472 RELAY OMRON MY2-AC110/120 DPDT

PartsTown

$90.21
(No reviews yet) Write a Review
SKU:
08-6472
Weight:
0.08 LBS
Shipping:
Calculated at Checkout
Length:
4.05
Label Option type:
rectangles
Net Price:
60.14
Product Taxonomy:
CulinaryDepot>>Parts
Manufacturer:
PartsTown
List Price:
88.44
MAP Price:
90.21
Trigger BC Integration:
Y-6/2/2026_6:00PM
Primary Image:
PartsTown_08-6472.png
Sale Price:
90.21
Taxonomy Weight:
0.08
email_price:
no
msrp_price:
no
call_price:
no
map_price:
no
login_price:
no
Keyfeatures5:
Compatible with MAR08-6472 Part Number
Keyfeatures4:
Lightweight 0.08 pounds component
Keyfeatures6:
Meets CSA compliance where required
Keyfeatures:
Compact DPDT switching for control circuits
Keyfeatures3:
Low-profile 4.05-inch length housing
Keyfeatures2:
Rated for AC110/120V coil operation
short_description:
PartsTown MAR08-6472 relay Omron MY2-AC110/120 DPDT offers reliable double-pole double-throw switching in a compact 4.05" by 1.3" size and weighs 0.08 pounds.
Ship From:
60101
Lead Time:
2 - 3 Business Days
Adding to cart… The item has been added
Stop compromising reliability for convenience. This industrial relay delivers precise control and consistent switching for high-demand electrical systems, enabling uninterrupted operation across commercial kitchen equipment and support infrastructure. Designed for professional environments, this component provides dependable performance under continuous cycling and frequent load transitions.
LongDescription#@#NA#@@#Cleaning Instructions#@#Wipe relay exterior with a soft cloth and mild detergent; avoid water ingress into terminals. Use isopropyl alcohol on contacts if corrosion appears. Inspect mounting screws and insulation for damage weekly and tighten or replace parts as needed. Clean surrounding high-touch areas—menu covers, chair backs, salt shakers, door handles—to prevent contamination, deter pests, and support health-code compliance, preserving customer perception and equipment longevity.#@@#Additional Info#@#PartsTown MAR08-6472 relay OMRON MY2-AC110/120 DPDT offers double-pole double-throw switching for commercial equipment, rated for AC110/120 V, with a compact 4.05" by 1.3" profile and 0.08 pounds weight, CSA-recognized for foodservice reliability.#@@#General Info#@#Description #@# Stop compromising reliability for convenience. This industrial relay delivers precise control and consistent switching for high-demand electrical systems, enabling uninterrupted operation across commercial kitchen equipment and support infrastructure. Designed for professional environments, this component provides dependable performance under continuous cycling and frequent load transitions. #@@# Relay Form Factor#@# Omron MY2 DPDT configuration provides two changeover contacts for flexible circuit control, enabling simultaneous switching of separate circuits with a single coil. Engineers can implement common control schemes without adding extra relays, reducing panel complexity and wiring labor. #@@# Coil Voltage Specification#@# Rated for 110/120 volt AC coil operation, this relay fits standard North American control circuits and simplifies integration with existing 120 volt control transformers. Technicians gain straightforward replacement compatibility and avoid coil mismatch issues during maintenance. #@@# Compact Dimensions#@# Measuring approximately 4.05 by 1.3 inches in footprint and depth, the relay fits compact control enclosures and modular racks used in culinary and facility equipment. Installers maintain service access while conserving panel space for additional components. #@@# Low Mass Construction#@# With a nominal mass near 0.08 pounds, the relay reduces strain on DIN rail clips and socket mounts, lessening mechanical stress during vibration and transport. Maintenance staff experience easier handling and lower risk of mount failure in mobile or high-traffic installations. #@@# Dual Pole Switching#@# DPDT contacts allow independent control of two circuits or provide redundant switching for safety interlocks and alarm circuits. Facility managers achieve layered control logic without adding separate contactors, improving system responsiveness and failover capability. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Install the 08-6472 RELAY OMRON MY2-AC110/120 DPDT according to CSA and manufacturer guidelines, verifying proper coil voltage and terminal wiring before operation. Inspect connections weekly for corrosion and torque loose screws to specified values. Clean contacts with contact cleaner and a lint-free cloth; replace the relay if pitting exceeds 0.01 inches. Monitor ambient temperature and mount on vibration-isolating hardware. Log maintenance actions and parts replaced for audit compliance.