Stop compromising durability for outdoor operation. This walk-in cooler delivers engineered thermal control and field-ready construction, enabling consistent cold storage in exposed environments while reducing installation complexity and service interruptions. Owners get a factory-tested self-contained refrigeration capsule that uses low-GWP R-290 refrigerant and operates on standard 115v power for straightforward site integration.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug unit and lock out power at 115v before cleaning. Remove food and debris, then wash interior walls and floor with mild detergent and warm water; rinse thoroughly. Clean door gasket and membrane roof with non-abrasive cleaner; inspect seals and hinges. Brush condenser and R-290 capsule pak coils to remove grease and dust. Dry all surfaces completely to prevent corrosion. Repeat weekly in high-use settings to reduce bacteria, fire risk, energy waste, and equipment failure.#@@#Additional Info#@#Norlake KODB771012-C outdoor cooler measures 91" H x 120" W x 144" D, using R-290 refrigeration on 115v/60/1-Ph.#@@#General Info#@#Description #@#
Stop compromising durability for outdoor operation. This walk-in cooler delivers engineered thermal control and field-ready construction, enabling consistent cold storage in exposed environments while reducing installation complexity and service interruptions. Owners get a factory-tested self-contained refrigeration capsule that uses low-GWP R-290 refrigerant and operates on standard 115v power for straightforward site integration.
#@@# Embossed Steel#@#
The unit uses 26 gauge embossed coated steel on both interior and exterior surfaces to resist corrosion and mechanical wear. Facility managers maintain hygienic surfaces and minimize repair cycles because the finish stands up to repeated cleaning and outdoor exposure.
#@@# Self Contained#@#
A factory-installed self-contained refrigeration system concentrates mechanical components into a single capsule, simplifying commissioning and service workflows. Technicians access standardized parts and diagnostics without routing remote condensing units across the site, which reduces installation labor and service time.
#@@# R-290 Refrigerant#@#
The refrigeration employs R-290 refrigerant to achieve efficient heat transfer and reduced environmental impact compared with older refrigerants. Operators see lower running currents and favorable thermodynamic performance while complying with modern efficiency expectations.
#@@# With Floor#@#
The cooler comes complete with an integrated floor to provide immediate usability and consistent thermal separation from grade. Food service staff avoid on-site floor fabrication and maintain uniform load distribution for stored products, supporting operational safety and inventory protection.
#@@# Self Closing Door#@#
A self-closing door mechanism pairs with a locking deadbolt handle to secure cold storage and reduce energy loss from accidental propping. Managers maintain target temperatures more consistently and lower compressor cycling through controlled access behavior.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect seals and hinges weekly; lubricate hinges with food-grade lubricant and replace worn gaskets to preserve airflow integrity. Clean condenser coils monthly using a brush and low-pressure air to maintain heat transfer efficiency. Sanitize interior panels and floor with a neutral pH detergent; rinse and dry to prevent corrosion on 26 gauge coated steel. Monitor refrigerant pressures and verify R-290 handling by certified technicians; document maintenance and CSA/UL compliance records.