Stop compromising on performance when storage and sanitation are crucial. This indoor walk-in cooler ensures consistent +35°F temperature control, features an integrated floor, and boasts durable coated steel construction to support continuous foodservice operations. Operators benefit from a compact 10' x 10' cooler that installs indoors and operates on standard 115 volts, fitting seamlessly into existing electrical systems.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug power and lock out the circuit before cleaning the Norlake KLB771010-C cooler. Remove stored product and wash interior walls, floor, and door with mild detergent and a non-abrasive cloth. Rinse with clean water and dry completely to prevent corrosion. Clean condenser coils and R-290 capsule pak components per manufacturer intervals to maintain efficiency and reduce fire risk. Inspect door seals and deadbolt handle; replace damaged seals.#@@#Additional Info#@#Norlake's KLB771010-C walk-in cooler is 91" H x 120" W x 120" D. It features a self-contained +35°F Kold Locker, 26-gauge coated steel, self-closing door, R-290 refrigeration, 115 volts, and is UL certified.#@@#General Info#@#Description #@#
Stop compromising on performance when storage and sanitation are crucial. This indoor walk-in cooler ensures consistent +35°F temperature control, features an integrated floor, and boasts durable coated steel construction to support continuous foodservice operations. Operators benefit from a compact 10' x 10' cooler that installs indoors and operates on standard 115 volts, fitting seamlessly into existing electrical systems.
#@@# Coated Steel#@#
The unit employs 26 gauge embossed coated steel on both interior and exterior surfaces to resist corrosion and facilitate cleaning in busy kitchens. Technicians value the rigid panel construction for long-term dimensional stability and minimal maintenance.
#@@# Self-Contained Cooling#@#
A self-contained refrigeration system utilizing R-290 refrigerant ensures efficient heat transfer while eliminating the need for remote condensing equipment. Facility managers enjoy simplified installation and reduced piping runs, which lower labor costs and potential leak points.
#@@# Temperature Control#@#
Engineers design the cooler to maintain +35°F for safe cold storage of perishable inventory under steady load conditions. Staff depend on consistent temperatures to safeguard food quality and extend hold times.
#@@# Integrated Floor#@#
The included floor offers a sealed storage surface that aligns with the cooler envelope, simplifying installation logistics. Maintenance teams benefit from fewer site-prep tasks and enhanced sanitation control.
#@@# Secure Access#@#
A self-closing door with a locking deadbolt handle improves product security and minimizes accidental door openings. Supervisors can reduce energy loss and limit unauthorized access during operating hours.
#@@# Standard Power#@#
The design operates on 115v, 60 hertz, single-phase electrical service, aligning with common kitchen circuits and avoiding the need for special power upgrades. Project planners can streamline electrical coordination and reduce upfront installation costs.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect condenser and fan assemblies monthly; remove debris and dust to maintain rated airflow and cooling capacity. Verify door gasket integrity and adjust hinges so the self-closing door seals uniformly; replace seals showing cracks or compression. Flush floor drains and sanitize interior surfaces with a mild detergent solution; rinse thoroughly. Confirm electrical connections and 115v supply before servicing. Record maintenance actions and refrigerant checks for regulatory compliance.