Skip to main content

Micro Matic PP4301-VP Pro-Line Power Pack Vertical Pump

Micro Matic

$308.41
(No reviews yet) Write a Review
SKU:
PP4301-VP
Weight:
0.00 LBS
Shipping:
Calculated at Checkout
SKU Number:
PP4301-VP__1152
Filter Type:
Pumps
email_price:
no
Tags:
Draft Beer Pump Type Tap Parts
Label Option type:
rectangles
Net Price:
272.25
msrp_price:
no
Ship From:
34604
Product Taxonomy:
CulinaryDepot>>Commercial Refrigerator>>Refrigeration Parts and Accessories>>Bar Refrigeration Draft Parts and Accessories>>Couplers, Distributors, & Regulators
call_price:
no
map_price:
no
Mfr Toll Free:
(866) 327-4159
Packed By:
1 Each
add_to_cart:
no
MAP Price:
308.41
Manufacturer:
Micro Matic
login_price:
no
List Price:
605.00
Trigger BC Integration:
Y-6/23/2026_6:00PM
Filter_Manufacturer:
Micro Matic
Filter_Type:
Pumps
Primary Image:
Micro Matic_PP4301-VP.png
warranty:
Micro Matic_PP4301-VP_1.pdf
Sale Price:
308.41
Keyfeatures5:
Direct-fit for PP4301-VP systems
Keyfeatures4:
CSA-listed components ensure safety
Keyfeatures6:
Optimized for commercial draft beer
Keyfeatures:
Compact vertical pump saves space
Keyfeatures3:
Durable construction cuts maintenance downtime
Keyfeatures2:
High-flow design ensures consistent pours
short_description:
Micro Matic PP4301-VP Pro-Line Power Pack vertical pump provides consistent pressure and reliable flow for draft beer systems in high-demand venues.
Lead Time:
2 - 3 Business Days
PRO:
yes
Adding to cart… The item has been added
Stop sacrificing flow control for installation ease. This vertical pump delivers consistent pressure and reliable throughput to keep draft lines operating at peak performance while fitting tight underbar footprints with a compact vertical design. Operators gain predictable flow rates and straightforward maintenance access, reducing service interruptions and supporting continuous service in high-traffic environments.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug the pump and close supply valves before cleaning. Remove external covers and wipe housing with a mild detergent solution and a soft cloth. Flush internal lines with potable water, then circulate a recommended cleaner at manufacturer concentration for 5–10 minutes. Rinse thoroughly until rinse water shows no residue. Inspect seals and fittings; replace worn components. Dry all parts completely and reassemble. Record service date and follow CSA guidelines for periodic maintenance.#@@#Additional Info#@#Micro Matic PP4301-VP Pro-Line Power Pack Vertical Pump ensures consistent flow for draft beer systems, works with standard couplers and regulators, and mounts vertically for compact bars; CSA-listed components support high-volume service.#@@#General Info#@#Description #@# Stop sacrificing flow control for installation ease. This vertical pump delivers consistent pressure and reliable throughput to keep draft lines operating at peak performance while fitting tight underbar footprints with a compact vertical design. Operators gain predictable flow rates and straightforward maintenance access, reducing service interruptions and supporting continuous service in high-traffic environments. #@@# Flow Efficiency#@# This pump maintains steady pressure across typical draft systems, ensuring uniform pour profiles and minimizing foam. Technicians can calibrate output quickly, preserving product quality and reducing waste during peak shifts. #@@# Compact Vertical Design#@# Engineers positioned the motor and impeller vertically to save counter and cellar space, allowing installation in narrow compartments and beneath coolers. Service personnel can reach key components without major disassembly, which accelerates routine inspections. #@@# Durable Construction#@# Manufacturers used corrosion-resistant materials for wetted parts to withstand cold, humid cellar conditions and alcohol exposure. Maintenance teams can extend service intervals and avoid frequent part replacement in demanding environments. #@@# Service-Friendly Access#@# Designers included removable panels and accessible fittings so technicians can perform diagnostics and part swaps without specialized tools. Onsite crews complete repairs faster, restoring service and reducing downtime costs. #@@# Compliance and Safety#@# This unit meets industry electrical and sanitation standards and integrates with common draft regulators and couplers for compatibility. Managers can maintain regulatory compliance and protect product integrity during daily operation. #@@# Performance Integration#@# Field-tested flow characteristics match standard draft tap assemblies and refrigeration setups for predictable results. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect pump seals weekly and replace any worn components to prevent leaks and contamination. Flush lines with potable water after each service period and sanitize using a manufacturer-approved cleaner to remove biofilm and scale. Lubricate moving parts monthly with food-grade lubricant and torque fasteners to specified values. Monitor flow rate and pressure daily; document readings and address deviations immediately to maintain consistent dispense performance.