Skip to main content

Micro Matic MV021 Leak Sensor Wand for Handheld Analyzer

Micro Matic

$437.94
(No reviews yet) Write a Review
SKU:
MV021
Weight:
0.00 LBS
Shipping:
Calculated at Checkout
Filter Type:
Detection Monitors
email_price:
no
Tags:
CO2 Detection Monitor
Label Option type:
rectangles
Net Price:
386.60
msrp_price:
no
Ship From:
34604
Product Taxonomy:
CulinaryDepot>>Commercial Refrigerator>>Refrigeration Parts and Accessories>>Bar Refrigeration Draft Parts and Accessories>>Couplers, Distributors, & Regulators
call_price:
no
map_price:
no
Mfr Toll Free:
(866) 327-4159
Packed By:
1 Each
add_to_cart:
no
MAP Price:
437.94
Manufacturer:
Micro Matic
login_price:
no
List Price:
859.10
Trigger BC Integration:
Y-6/24/2026_6:00PM
Filter_Manufacturer:
Micro Matic
Filter_Type:
Detection Monitors
Primary Image:
Micro Matic_MV021.jpg
warranty:
Micro Matic_MV021_1.pdf
Sale Price:
437.94
SKU Number:
MV021__1152
Keyfeatures5:
Lightweight for prolonged inspections
Keyfeatures4:
Compatible with Micro Matic analyzers
Keyfeatures6:
Meets detection monitor standards
Keyfeatures:
Compact wand for gas analyzers
Keyfeatures3:
Rugged for professional use
Keyfeatures2:
Detects CO2 leaks quickly
short_description:
Micro Matic MV021 leak sensor wand integrates with handheld gas analyzers to detect CO2 leaks quickly and reliably. It delivers rugged construction, CSA-compatible design, and straightforward operation for beverage service professionals.
Lead Time:
2 - 3 Business Days
PRO:
yes
Adding to cart… The item has been added
Stop guessing where a leak originates. This leak sensor wand transforms handheld gas analyzers into precise CO2 detection tools, enabling technicians to locate leaks quickly and reduce product loss and safety risks. Installers and service teams gain a compact, purpose-built probe that integrates seamlessly with existing analyzers for targeted monitoring and efficient maintenance.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug analyzer and remove probe. Mix mild detergent with warm water (use gallons or liters as needed). Wipe wand and housing with a soft cloth; scrub crevices with a soft brush. Rinse thoroughly and dry with lint-free cloth. Inspect seals and connectors; replace damaged parts. Calibrate sensor per Micro Matic MV021 manual after cleaning. Clean daily in high-use environments to stop sickness, prevent fires, save energy, avoid breakdowns, and pass CSA inspections.#@@#Additional Info#@#Micro Matic MV021 Leak Sensor Wand attaches to gas analyzers, detects CO2 leaks quickly, supports CSA workflows, fits standard couplers, and helps technicians locate leaks and verify repairs with minimal downtime.#@@#General Info#@#Description #@# Stop guessing where a leak originates. This leak sensor wand transforms handheld gas analyzers into precise CO2 detection tools, enabling technicians to locate leaks quickly and reduce product loss and safety risks. Installers and service teams gain a compact, purpose-built probe that integrates seamlessly with existing analyzers for targeted monitoring and efficient maintenance. #@@# Probe Precision#@# Microstructured sensor geometry delivers focused detection at nozzle and coupling interfaces, allowing technicians to identify emission points within seconds. Field technicians obtain clear signals without repositioning, which reduces inspection time and lowers labor costs per check. #@@# Handheld Compatibility#@# Engineered for seamless connection to compatible analyzers, the wand retains analyzer functionality while extending detection reach to confined spaces. Service crews maintain full control and sensitivity when inspecting under coolers, behind fittings, or inside kegs and line runs. #@@# Durable Construction#@# Stainless steel and reinforced polymer components resist mechanical stress and exposure typical in bar and kitchen environments. Maintenance teams rely on consistent operation through routine daily use and periodic cleaning procedures. #@@# Ergonomic Control#@# Textured grip and optimized balance promote sustained single-handed operation during extended inspections, reducing operator fatigue. Technicians maintain steady positioning for accurate readings in tight or elevated locations. #@@# Rapid Response#@# Sensor electronics respond to CO2 concentration changes within fractions of a second, allowing personnel to trace transient leaks that other methods might miss. Managers reduce downtime by repairing leaks before they enlarge or trigger secondary equipment issues. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the Micro Matic MV021 leak sensor wand before each shift and verify secure connection to the handheld analyzer. Calibrate the analyzer per manufacturer schedule and record calibration results. Clean the wand tip with isopropyl alcohol and lint-free cloth after exposure to contaminants. Replace damaged cables, seals, or tip components immediately. Store the wand in a dry, temperature-controlled case and inventory spare tips and batteries regularly.