Stop sacrificing time for compatibility. This vertical converter assembles a compact draft tap solution that replaces multiple components while maintaining flow integrity and service speed. Designed for high-use bars and institutional pouring points, the unit arrives with pre-attached hoses and a faucet to streamline installation and reduce labor exposure.
Features And Benefits
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug the draft system and close gas and liquid valves. Remove faucet and hoses for separate cleaning. Prepare a 1:100 bleach solution or NSF-approved sanitizing cleaner; soak removable parts for 5–10 minutes, then scrub with a soft brush. Flush lines with clean water until no residue remains. Wipe exterior surfaces with non-abrasive cleaner and inspect seals and fittings. Reassemble components, purge air, and test flow. Clean weekly to prevent contamination, fires, and equipment failure.#@@#Additional Info#@#Micro Matic 7977H6B vertical converter integrates hose assemblies and a faucet for draft systems, allowing quick keg coupler conversion while ensuring pressure integrity and flow consistency.#@@#General Info#@#Description #@#
Stop sacrificing time for compatibility. This vertical converter assembles a compact draft tap solution that replaces multiple components while maintaining flow integrity and service speed. Designed for high-use bars and institutional pouring points, the unit arrives with pre-attached hoses and a faucet to streamline installation and reduce labor exposure.
Features And Benefits
#@@# Vertical Converter#@#
This converter aligns keg output to standard draft lines, enabling direct vertical mounting in confined towers and column assemblies. Installers achieve consistent pressure routing and simplified line runs, which reduces on-site adjustments and improves pour stability.
#@@# Pre-Attached Hoses#@#
The assembly includes factory-fitted hoses sized for commercial draft systems, eliminating the need to source and cut tubing during setup. Technicians complete hook-ups faster, minimizing downtime and lowering installation labor costs.
#@@# Integrated Faucet#@#
The package contains a compatible faucet matched to the converter, providing a sealed interface between keg gas and serving line. Operators maintain a hygienic, controlled dispense point that reduces leakage risk and preserves carbonation levels.
#@@# Space Efficient Design#@#
Engineers designed the unit for vertical orientation to maximize space in narrow towers and compact backbar installations. Facilities conserve cabinet volume and free adjacent areas for additional refrigeration or storage.
#@@# Material Durability#@#
Manufacturers specify components to withstand typical barroom pressures and frequent cycling during service hours. Staff expect long-term resistance to wear, fewer replacements, and reduced parts inventory requirements.
#@@# Compliance Ready#@#
Assemblies ship with components that meet common industry standards for draft systems and installation practices, supporting CSA-related requirements where applicable. Maintenance teams document compliance more easily and simplify inspections.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the Micro Matic 7977H6B vertical converter and hoses weekly for leaks and wear. Remove the faucet and soak in warm, soapy water; rinse and sanitize with a food-safe solution before reassembly. Flush lines with approved cleaner after each keg change and purge with CO2 to prevent oxidation. Verify hose clamps and fittings torque to manufacturer specs. Log maintenance actions and replace seals or gaskets at first sign of degradation.