Power through high-traffic openings with an industrial air curtain engineered for consistent separation, energy retention, and simplified maintenance. This unheated unit pairs dual 1/2 HP motors with a wide discharge to maintain interior climate control while allowing uninterrupted foot and equipment flow. Facility managers will appreciate a powder-coated aluminum cabinet that resists corrosion and simplifies cleaning for long service life.
LongDescription#@#NA#@@#Cleaning Instructions#@#Clean the air curtain regularly to prevent cross-contamination and preserve appearance. Mix mild detergent with warm water (do not exceed 2 gallons per 10 liters for rinsing), wipe external cabinet and louvers with a soft cloth, then dry. Remove and vacuum intake grille monthly; inspect motors and fasteners for wear. Sanitize high-touch surfaces like control switches and mounting hardware to reduce germ transfer, avoid pest attraction, and help meet CSA and health-code expectations.#@@#Additional Info#@#Mars Air Systems PH1084-2UH-PW Phantom 10 air door suits 84"–95" openings. It has a 26" depth aluminum cabinet in pearl white, uses two 1/2 HP motors at 460v/60/3-Ph, is ETL sanitation listed, weighs 125 pounds, and has a max opening of 8 Ft.#@@#General Info#@#Description #@#
Power through high-traffic openings with an industrial air curtain engineered for consistent separation, energy retention, and simplified maintenance. This unheated unit pairs dual 1/2 HP motors with a wide discharge to maintain interior climate control while allowing uninterrupted foot and equipment flow. Facility managers will appreciate a powder-coated aluminum cabinet that resists corrosion and simplifies cleaning for long service life.
#@@# Dual Motor#@#
Two motors deliver redundant airflow and maintain specified performance even under continuous cycles. Service teams access each 1/2 HP motor for streamlined inspection and replacement, reducing downtime and labor hours.
#@@# Wide Coverage#@#
Designed for openings from 84 inches to 95 inches, the unit establishes a continuous air barrier across large doorways. Operations that handle pallet traffic or frequent pedestrian flow retain conditioned air and reduce infiltration across the full span.
#@@# Voltage Compatibility#@#
Specified for 460 volts and configured for 60 hertz 3-Ph power, the unit integrates with industrial electrical systems. Electricians achieve straightforward installation without field conversions, supporting reliable operation on intended supply circuits.
#@@# Compact Depth#@#
The 26-inch depth provides an effective footprint that fits tight mounting zones above doors. Installers gain flexibility when clearance is limited, allowing the unit to sit close to overhead structures while maintaining optimal airflow geometry.
#@@# Unheated Design#@#
This unheated model focuses energy on air movement rather than heat output, lowering operating costs where supplemental heating proves unnecessary. Building managers control interior temperature with existing HVAC while the air curtain minimizes exchange losses.
#@@# Durable Finish#@#
Pearl white powder coat on an aluminum cabinet resists wear and simplifies sanitation procedures, and the ETL listing confirms compliance with applicable safety standards.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the PH1084-2UH-PW air curtain monthly. Remove dust from the intake grille with a vacuum and soft brush to maintain airflow and prevent motor overheating. Lubricate bearings every six months per Manufacturer recommendations and verify both 1/2 HP motors operate without abnormal noise; replace worn belts or fasteners immediately. Confirm electrical connections at 460v 3-Ph are tight and check for corrosion; ensure hertz matches 60 and phase is 3-Ph before commissioning.