Handle heavy foot traffic without compromise: this unheated high-velocity air curtain delivers targeted air separation for wide openings while maintaining consistent performance under continuous use. Facility teams gain reliable control over indoor environments for doors up to 95 inches, utilizing robust construction and industry-compliant electrical ratings to match commercial installations. Installers will appreciate the clear specifications and serviceable components that simplify integration into existing systems.
LongDescription#@#NA#@@#Cleaning Instructions#@#Wipe exterior with mild detergent and a soft cloth; rinse and dry to prevent corrosion. Sanitize high-touch zones like control switches and access panels using an EPA-registered disinfectant; follow dwell time on label. Inspect inlet and grille monthly; vacuum debris and wipe blades with a damp cloth while power is off. Tighten mounting hardware quarterly. Regular cleaning prevents cross-contamination, supports health-code compliance, deters pests, and preserves finish.#@@#Additional Info#@#Mars Air Systems NH284-2UH-TS titanium silver air curtain provides unheated, high-velocity airflow for 84" doorways with two 1 HP motors at 460 volts/60 Hz/3-Ph; ETL-listed, 16" depth, 14" height, 235 pounds, supports up to 8 Ft. openings.#@@#General Info#@#Description #@#
Handle heavy foot traffic without compromise: this unheated high-velocity air curtain delivers targeted air separation for wide openings while maintaining consistent performance under continuous use. Facility teams gain reliable control over indoor environments for doors up to 95 inches, utilizing robust construction and industry-compliant electrical ratings to match commercial installations. Installers will appreciate the clear specifications and serviceable components that simplify integration into existing systems.
#@@# Cabinet Construction#@#
Galvanized steel cabinet resists corrosion and offers structural rigidity for continual operation in demanding settings. The titanium silver powder coat finish provides a durable external surface that reduces maintenance cycles and sustains a professional appearance.
#@@# High Velocity Flow#@#
Two 1 HP motors generate concentrated high-velocity airflow to form an effective barrier against outdoor air intrusion and airborne particulates. This configuration supports openings up to 95 inches and maintains separation at maximum opening heights of 8 feet.
#@@# Electrical Compatibility#@#
Designed for 460 volts, 60 hertz, 3-phase power, this unit matches standard industrial three-phase supplies and eases integration with existing electrical infrastructure. Specified voltage and phase reduce the need for onsite electrical modifications during installation.
#@@# Serviceability Features#@#
Two motors provide modular access for routine inspection and replacement, minimizing downtime in critical operations. Technicians can perform targeted maintenance without removing the entire assembly, ensuring efficiency.
#@@# Safety and Compliance#@#
ETL sanitation listing confirms adherence to applicable safety and performance standards for commercial settings. This listing supports regulatory acceptance and simplifies compliance documentation for facility managers, enhancing operational reliability.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the air curtain monthly for dust accumulation on the inlet and outlet grilles and remove deposits with a brush and vacuum to preserve airflow. Lubricate motor bearings per manufacturer intervals and torque accessible fasteners to specified values. Verify electrical connections at 460 volts, 60 hertz, 3-Ph for tightness and thermal integrity; replace damaged wiring. Clean exterior with mild detergent; avoid solvents. Record service actions and dates for CSA compliance.