Engineered for continuous operation, this 1 HP air-cooled remote condensing unit delivers reliable cooling capacity for commercial ice systems while minimizing floor heat load and service disruption. Designed for integration with IF-0900C style machines, the unit operates on 208/230 volts single-phase power and maintains performance across 60 Hz electrical systems with a rated 11.5 amps draw.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug the unit and lock out power. Remove panels and brush away debris from the condenser fins. Vacuum coils then wipe with a damp cloth and mild detergent. Check fan blades and motor for grease; degrease and tighten mounts. Inspect refrigerant lines and electrical connections; tighten as needed. Replace damaged gaskets and seals. Clean surrounding area to prevent airflow restriction. Perform monthly inspections to reduce fires, avoid breakdowns, save on energy, and pass CSA inspections.#@@#Additional Info#@#Manitowoc CVDF0900 air-cooled condensing unit for IF-0900C provides 1 HP output, operates at 208/230 volts, 60 Hz, 1-Ph, and draws 11.5 amps. It weighs 183 pounds, installs remotely to reduce kitchen heat, and meets CSA and cULus certifications.#@@#General Info#@#Description #@#
Engineered for continuous operation, this 1 HP air-cooled remote condensing unit delivers reliable cooling capacity for commercial ice systems while minimizing floor heat load and service disruption. Designed for integration with IF-0900C style machines, the unit operates on 208/230 volts single-phase power and maintains performance across 60 Hz electrical systems with a rated 11.5 amps draw.
#@@# Power-Dense Output#@#
The unit provides 1 HP cooling output optimized for commercial ice production, enabling steady condensing under sustained loads. Engineers will appreciate the consistent electrical characteristics of 208/230 volts and 60 Hz operation for predictable thermal control.
#@@# Compact Footprint#@#
At a depth of 24.13 inches, a width of 34 inches, and a height of 26 inches, the chassis fits tight rooftop or exterior wall installations. Technicians can site the condenser where floor space remains available while reducing indoor heat gain from central equipment.
#@@# Air-Cooled Efficiency#@#
The air-cooled design rejects heat to ambient air, eliminating the need for water hookups and reducing utility infrastructure. Operators benefit from simplified installation and lower ongoing water consumption measured in gallons for related systems.
#@@# Service-Friendly Construction#@#
Certified to CSA and cULus standards, the condensing unit meets safety and electrical compliance for commercial kitchens and institutional sites. Field service access on external panels supports routine maintenance and component replacement without extended downtime.
#@@# Electrical Compatibility#@#
Single-phase power and an 11.5 amp rating ensure straightforward circuit sizing and breaker selection for most facility electrical systems. Facility managers gain clarity on load planning when integrating the unit with existing distribution panels.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#Culinary Depot usually delivers Manitowoc CVDF0900 Remote Condensing Unit within # business days upon confirming cleared payment.#@@#Maintenance Guide#@#Maintain the Manitowoc CVDF0900 condensing unit by inspecting electrical connections monthly and tightening terminals at 208/230 volts. Clean condenser fins weekly with low-pressure air to ensure airflow. Replace filter-driers per service intervals and check refrigerant charge with manifold gauges. Lubricate fan motors quarterly and record amp draw; 11.5 amps indicates the correct load range.