Stop sacrificing durability for convenience when storing perishable stock. This indoor walk-in cooler merges robust construction with precise climate control, supporting high-volume operations while minimizing maintenance interruptions. Facility managers will benefit from consistent refrigeration performance tailored to commercial kitchens, cafeterias, hospitals, and large foodservice environments.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug the unit before cleaning and remove all contents. Empty drip pans and wipe interior walls with a mild detergent solution and a soft cloth. Scrub door gaskets and hinges with warm, soapy water and inspect for wear. Clean condenser coils using a brush or vacuum to improve efficiency. Remove grease from vents and filters to reduce fire risk. Rinse and dry all surfaces thoroughly. Reconnect power only after the unit is completely dry.#@@#Additional Info#@#Kolpak's PX7-0812-CT cooler is 90.25" H x 93" W x 139" D with a 1 HP R-448A unit for +38F. It has a galvalume design, NSF/UL certifications, floorless design, 2" thermometer, 115v power, and weighs 1,346 pounds.#@@#General Info#@#Description #@#
Stop sacrificing durability for convenience when storing perishable stock. This indoor walk-in cooler merges robust construction with precise climate control, supporting high-volume operations while minimizing maintenance interruptions. Facility managers will benefit from consistent refrigeration performance tailored to commercial kitchens, cafeterias, hospitals, and large foodservice environments.
#@@# Structure Built to Last#@#
Kolpak designed the unit with 26 ga. embossed galvalume for both interior and exterior panels, ensuring resistance to corrosion and durability for daily use in busy facilities. The panels interlock to create a tight seal, reducing thermal loss and limiting compressor runtime.
#@@# Optimized Footprint#@#
The cooler measures 90.25 inches high by 93 inches wide and 139 inches deep, providing approximately 8 foot by 12 foot nominal interior capacity without a built-in floor. Designers will appreciate the floorless configuration, allowing for seamless installation over existing flooring and flexible drain and utility routing.
#@@# Top Mounted Cooling#@#
A 1 HP top-mounted, self-contained refrigeration package utilizes R-448A refrigerant and delivers medium temperature control rated at +38F, ensuring product safety across varied loads. Technicians will find that the top mount arrangement simplifies service access and isolates mechanical noise from product storage areas.
#@@# Energy And Safety Controls#@#
The system operates on 115 volts and features a 2-inch dial thermometer for straightforward temperature monitoring. Certifications from NSF, cUL, and UL confirm compliance with commercial safety and sanitation standards. Engineers can integrate the unit into facility layouts, confident that regulatory requirements are met.
#@@# Sealing And Thermal Management#@#
Four-inch vinyl/foam screeds along joints create a continuous thermal barrier, minimizing air infiltration during door cycles and daily use.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect condenser coils monthly and remove dust with a soft brush and vacuum to preserve heat transfer. Clean interior panels and shelving weekly using a mild detergent solution and nonabrasive cloth; rinse and dry to prevent corrosion. Verify door gaskets for cracks and restore seal alignment; replace damaged gaskets immediately. Calibrate the 2" dial thermometer quarterly and record temperatures. Drain and defrost per manufacturer guidance; document maintenance actions.