Stop sacrificing storage integrity for speed. This indoor walk-in cooler delivers robust temperature control and modular flexibility while supporting heavy-use operations with reliable, code-compliant construction.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug electrical power and lock out the circuit before service. Empty the cooler and remove shelves. Wash interior surfaces with a mild soap solution and a soft cloth, paying attention to seals and corners. Clean condenser coils and fan blades with a brush and coil cleaner to maintain efficiency. Degrease door gaskets and check for wear; replace if torn. Rinse and dry all surfaces thoroughly. Reconnect power only after the unit is completely dry and temperature stabilizes.#@@#Additional Info#@#Kolpak's KFX8-1410-CR indoor cooler measures 102" H x 162" W x 116" D, operates at +35°F, and has a remote R-404A system for 208/230 volts. It features a 26-gauge galvalume design, 4" screeds, a 2" thermometer, and is NSF, cUL, UL certified.#@@#General Info#@#Description #@#
Stop sacrificing storage integrity for speed. This indoor walk-in cooler delivers robust temperature control and modular flexibility while supporting heavy-use operations with reliable, code-compliant construction.
#@@# Capacity Design#@#
The unit measures 102 inches high, 162 inches wide, and 116 inches deep, providing substantial refrigerated volume for high-throughput kitchens and institutional pantries. Operators gain consistent storage space that aligns with workflow patterns in restaurants, hospitals, and schools.
#@@# Temperature Control#@#
The system maintains a medium temperature at +35°F with a 2-inch dial thermometer for straightforward monitoring and adjustments. Facilities achieve stable product preservation using a remote refrigeration configuration charged for R-404A refrigerant.
#@@# Construction Materials#@#
Exterior and interior panels use 26-gauge embossed galvalume to resist corrosion and simplify cleaning in rigorous back-of-house environments. Maintenance teams benefit from durable surfaces that reduce lifecycle repair frequency and support sanitation protocols.
#@@# Floor Configuration#@#
The design ships floorless and incorporates 4-inch vinyl and foam screeds for a controlled perimeter seal when installed over existing flooring. Installers gain flexibility for retrofit applications while preserving thermal integrity and minimizing installation downtime.
#@@# Certifications and Electrical#@#
The walk-in carries NSF, cUL, and UL certifications and operates on 208/230 volts, supporting compliance and compatibility with commercial electrical systems. Managers receive documentation that facilitates inspections and ensures adherence to food safety standards.
#@@# Installation Flexibility#@#
Panels suit indoor installation with options for indoor/outdoor remote placement to separate the condensing unit from the cold room. Engineering teams reduce equipment noise and heat load in service areas while maintaining efficient refrigerant routing.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect condenser coils monthly; remove debris with a soft brush and vacuum to maintain efficiency. Calibrate the 2" dial thermometer quarterly and log readings to verify medium temperature (+35F). Sanitize interior surfaces with a mild, nonabrasive detergent; rinse and air dry to prevent corrosion. Check door gaskets for compression and replace if gaps exceed 1/8 inch. Confirm remote unit refrigerant level for R-404A and schedule annual service with a CSA or UL certified technician.