Stop sacrificing capacity for control. This indoor walk-in cooler delivers consistent medium-temperature performance while optimizing floor space, structural durability, and serviceability for high-traffic foodservice operations. Designed for remote refrigeration systems and built with robust galvalume panels, this unit supports continuous use in restaurants, hospitals, universities, and large catering facilities.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug the cooler and remove all food. Empty condensate trays and sweep the floorless base. Mix mild detergent in warm water; scrub interior Galvalume panels with a soft cloth and non-abrasive pad. Rinse surfaces and dry completely. Clean condenser coils and remote unit filters monthly to maintain airflow and reduce energy use. Inspect door seals and the 2" dial thermometer; replace faulty parts. Regular cleaning prevents contamination, fire risk, higher utility bills, and equipment failure.#@@#Additional Info#@#Kolpak's KFX8-1208-CR indoor cooler measures 102" H x 139" W x 93" D, operates at +35°F with R-404A refrigeration, and includes 26-gauge galvalume panels, floorless design, 4" vinyl/foam screeds, a 2" thermometer, and CSA, NSF, UL certifications.#@@#General Info#@#Description #@#
Stop sacrificing capacity for control. This indoor walk-in cooler delivers consistent medium-temperature performance while optimizing floor space, structural durability, and serviceability for high-traffic foodservice operations. Designed for remote refrigeration systems and built with robust galvalume panels, this unit supports continuous use in restaurants, hospitals, universities, and large catering facilities.
#@@# Exterior Galvalume#@#
The unit uses 26 gauge embossed galvalume on exterior surfaces to resist corrosion and maintain structural integrity under heavy use. Operators will benefit from a durable finish that reduces maintenance frequency and preserves appearance in demanding kitchen environments.
#@@# Floorless Design#@#
This cooler installs without an integral floor, enabling flexible placement over existing drains and sealed kitchen floors while simplifying integration with site utilities. Technicians can route plumbing and drains directly beneath the unit, which reduces installation time and eliminates on-site floor construction.
#@@# Remote Refrigeration#@#
The pre-charged remote refrigeration configuration supports R-404A refrigerant and separates the condensing equipment from the conditioned space to reduce heat load in kitchen areas. Facility managers will observe lower ambient heat and gain easier access to service points outside the food preparation zone.
#@@# Temperature Control#@#
A 2-inch dial thermometer provides straightforward temperature monitoring for medium-temp applications at approximately +35°F. Staff will perform quick visual checks and maintain required cold chain conditions for perishables without complex programming.
#@@# Certified Compliance#@#
This model carries NSF, cUL, and UL certifications, ensuring compliance with health and safety standards for commercial food storage. Purchasing teams will rely on documented approvals for inspections and risk management across institutional accounts.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect condenser coils monthly and remove dust with a soft brush to sustain airflow. Drain refrigeration lines per manufacturer schedule and verify remote unit connections for leaks using approved refrigerant R-404A detection methods. Clean interior galvalume panels with a mild, pH-neutral detergent and a soft cloth; avoid abrasive pads. Test door seals weekly and replace worn gaskets. Record thermostat (+35F) readings daily and service compressors at first performance deviation.